Laserfiche WebLink
Environmental Health Department <br />Time In: <br />10:43 am <br />10:12 am <br />Time Out: <br />Program Element: 3612 - PUBLIC POOL/SPA - ADDITIONAL <br />Telephone: Owner/Operator: GATEWAY CROSSING LLC <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 3580 W GRANT LINE RD, TRACY 95304 <br />Date: 06/22/2022Name of Facility: GATEWAY CROSSING APTS <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #10 Disinfectant Residual MAJOR <br />OBSERVATIONS: The chlorine level of the spa is 2.2ppm. Increase the chlorine level to the range of 3.0-10.0ppm. Correct <br />immediately or face possible closure. <br />A few ounces of chlorine were added to the spa. The spa's chlorine level was re-checked: 5.6ppm (pH re-checked at 7.6) <br />CALCODE DESCRIPTION: Public pools, when open or in use, shall be disinfected continuously by approved chemicals and shall maintain <br />the following concentrations: 1.0 ppm to 10.0 ppm free chlorine without cyanuric acid, 2.0 ppm to 10.0 ppm free chlorine with cyanuric acid <br />or 2.0 ppm bromine. Spas, wading pools, and spray grounds shall maintain the following concentrations: 3.0 ppm to 10.0 ppm free <br />chlorine or 4.0 ppm bromine. (CCR 65529) <br /> #11 Combined Chlorine Concentration <br />OBSERVATIONS: The combined chlorine level of the spa is 1.2ppm. Take action to reduce the combined chlorine level to <br />0.4ppm or less. Correct by 1 week. <br />CALCODE DESCRIPTION: Pool operator shall maintain combined chlorine concentration below 0.4 ppm. (CCR 65530) Chemical quality <br />of pool water and indoor air quality at the pool site shall not cause adverse physiological effects, such as irritation of the eyes, lungs, or <br />skin. (CCR 65531) <br />OVERALL INSPECTION NOTES AND COMMENTS <br />OBSERVATIONS <br />Flow rate:gpm <br />pH: <br />Chlorine:ppm <br />Cyanuric acid:ppm <br />Temp:º F 60 <br />7.8 <br />2.2 <br /><30 <br /> 100.60 <br />Combined chlorine:ppm1.2 <br />NOTES <br />influent: 16 <br />effluent: 16 <br />No signature obtained <br />Report typed at the office 1:50p-1:56p <br />Page 1 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0024353 PR0542385 SC001 06/22/2022 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD