My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2022
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BIANCHI
>
1633
>
3600 - Recreational Health Program
>
PR0518496
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/29/2022 11:06:59 AM
Creation date
6/29/2022 11:03:26 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3600 - Recreational Health Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0518496
PE
3611
FACILITY_ID
FA0013939
FACILITY_NAME
TORCELLO APARTMENTS
STREET_NUMBER
1633
STREET_NAME
BIANCHI
City
STOCKTON
Zip
95210
APN
09614050
CURRENT_STATUS
01
SITE_LOCATION
1633 BIANCHI A3
P_LOCATION
01
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
3
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br />Facility Name and Address: TORCELLO APARTMENTS, 1633 BIANCHI , STOCKTON 95210 <br />Swimming Pool Official Inspection Report <br /> #22 Skimmer Assembly <br />OBSERVATIONS: Observed one missing and one damaged o-ring. Provide and replace o-rings within 1 week. <br />Observed missing weir doors and float assemblies. Provide weir doors and float assemblies within 1 week. <br />CALCODE DESCRIPTION: Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br />maintained in accordance with manufacturer specifications. (CBC 3136B) <br /> #30 Pool Equipment and Plumbing Maintained <br />OBSERVATIONS: Observed some leaking from back filter cap. Repair leak within 3 days. <br />CALCODE DESCRIPTION: All equipment related to pool operations shall be installed and maintained in accordance with manufacturer's <br />specifications and shall comply with applicable requirements established by applicable NSF/ANSI-50 performance standards. (CBC <br />3123B) <br /> #35 Flow Meters <br />OBSERVATIONS: The flow meters for both filters were not working. Repair/replace flow meters within 1 week. <br />CALCODE DESCRIPTION: Flow meters shall be provided on each recirculation system and shall be installed in accordance with <br />manufacturer's specifications. (CBC 3125B) <br /> #36 Pressure and Vacuum Gauges <br />OBSERVATIONS: The effluent pressure gauges did not appear to be working. Repair/replace effluent gauges within 1 <br />week. <br />The back filter influent pressure gauge was damaged. Repair/replace pressure gauge within 1 week. <br />CALCODE DESCRIPTION: Pressure and vacuum gauges shall be provided for each pump system. (CBC 3125B) <br />OVERALL INSPECTION NOTES AND COMMENTS <br />OBSERVATIONS <br />Flow rate:gpm <br />pH: <br />Chlorine:ppm <br />Cyanuric acid:ppm <br />Temp:º F <br />7.6 <br />2.6 <br />50 Combined chlorine:ppm <br />NOTES <br />Influent: front - 30 PSI , back - 17 PSI <br />Effluent: not working. <br />If there is a greater than 10 PSI pressure difference between the influent and effluent pressure gauges then clean/replace the <br />cartridge filters. <br />Page 2 of 3EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0013939 PR0518496 SC001 06/22/2022 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD
The URL can be used to link to this page
Your browser does not support the video tag.