Laserfiche WebLink
Environmental Health Department <br />Time In: <br />10:16 am <br />10:03 am <br />Time Out: <br />Program Element: 3611 - PUBLIC POOL/SPA - PRIMARY <br />Telephone: (209) 951-4391 Owner/Operator: PATMON COMPANY INC <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 8429 MARINERS DR, STOCKTON 95219 <br />Date: 06/07/2022Name of Facility: HARBOR ISLE APARTMENTS <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #14 Chemical Water Test Kit <br />OBSERVATIONS: Pool test kit is lacking. <br />Provide <br />CALCODE DESCRIPTION: Pool operator shall maintain a test kit for measuring the disinfectant residual, combined chlorine, pH, and <br />cyanuric acid (if used) at the pool. Test kit shall be available at all times the pool is in use. Chlorine and bromine test kits shall be DPD <br />type. Chlorine test kits shall be capable of testing for free and total chlorine, so that combined chlorine concentrations can be determined. <br />(CCR 65529) <br /> #18 Pool Shell and Tile <br />OBSERVATIONS: Slight chipping observed on pool shell at the shallow end of the pool. <br />Pool shell shall be smooth. <br />CALCODE DESCRIPTION: Pool shells shall be white and have a smooth waterproof interior finish that will withstand repeated brushing, <br />and scrubbing. A spa pool may be finished in a light color other than white when approved by the enforcement agency. (CBC 3108B) <br /> #22 Skimmer Assembly <br />OBSERVATIONS: One float valve assembly is lacking. <br />Provide. <br />2 weirs are lacking from skimmers. <br />Provide. <br />CALCODE DESCRIPTION: Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br />maintained in accordance with manufacturer specifications. (CBC 3136B) <br /> #36 Pressure and Vacuum Gauges <br />OBSERVATIONS: Effluent gauge is not operative and reads 0. <br />Provide operative effluent gauge. <br />CALCODE DESCRIPTION: Pressure and vacuum gauges shall be provided for each pump system. (CBC 3125B) <br />Page 1 of 2EHD 36-01 Rev. 06/30/15 Swimming Pool OIR <br />FA0002829 PR0360367 SC001 06/07/2022 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjcehd.com