Laserfiche WebLink
Environmental Health Department <br />Time In: <br />11:54 am <br />11:36 am <br />Time Out: <br />Program Element: 3611 - PUBLIC POOL/SPA - PRIMARY <br />Telephone: Owner/Operator: STOCKTON 9-B LLC <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 2317 ROSEMARIE LN, STOCKTON 95207 <br />Date: 06/14/2022Name of Facility: VENETIAN BRIDGES APTS WEST <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #3 Safety Signs <br />OBSERVATIONS: The "Diarrhea" safety sign (Notice Persons Having Currently Active Diarrhea Or Who Have Had Active <br />Diarrhea Within The Previous 14 Days Shall Not Be Allowed To Enter The Pool Water) is not posted. All safety signs shall <br />be posted. Correct today. <br />CALCODE DESCRIPTION: Pool operator shall keep safety signs well maintained. (CCR 65535) Safety signs shall have clearly legible <br />letters or numbers not less than 4 inches high, unless otherwise specified. Safety signs shall be affixed to a wall, pole, gate, or similar <br />permanent structure in a location visible to all pool users, unless otherwise specified. (CBC 3120B) <br /> #7 Pool Deck <br />OBSERVATIONS: Valve on deck lacks cover. Provide cover today. (REPEAT) <br />CALCODE DESCRIPTION: An unobstructed 4-foot wide deck of concrete or like material shall be provided and maintained flush with the <br />top of the pool coping. Deck shall extend completely around the pool and shall further extend 4 feet on both sides and to the rear of any <br />diving board, ADA device, or slide. (CBC 3114B) Pool operator shall keep the pool deck well maintained. (CCR 65535) <br /> #22 Skimmer Assembly <br />OBSERVATIONS: Skimmer on south side of pool lacks a weir. Install weir in two weeks. <br />CALCODE DESCRIPTION: Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br />maintained in accordance with manufacturer specifications. (CBC 3136B) <br />OVERALL INSPECTION NOTES AND COMMENTS <br />OBSERVATIONS <br />Flow rate:gpm <br />pH: <br />Chlorine:ppm <br />Cyanuric acid:ppm <br />Temp:º F 75 <br />7.2 <br />5.4 <br /><30 <br /> 75.00 <br />Combined chlorine:ppm <br />NOTES <br />West pool <br />Influent 10 psi <br />Effluent 2 psi <br />Contact Frank at 916-213-9735 for pool access <br />Page 1 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0001727 PR0360278 SC001 06/14/2022 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD