Laserfiche WebLink
Environmental Health Department <br />Time In: <br />10:45 am <br />10:15 am <br />Time Out: <br />Program Element: 3611 - PUBLIC POOL/SPA - PRIMARY <br />Telephone: (408) 984-5600 Owner/Operator: POLO RUN FAMILY APARTMENTS LP <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 8165 PALISADES DR, STOCKTON 95210 <br />Date: 06/14/2022Name of Facility: POLO RUN APARTMENTS <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #12 pH Level MAJOR <br />OBSERVATIONS: The pH level in the pool is below 7.0. The pool is closed and will remain closed. The pool must be <br />reinspected by the Environmental health Department if it is reopened. <br />CALCODE DESCRIPTION: Pool operator shall maintain pH between 7.2 and 7.8. (CCR 65530) <br /> #16 Water Clarity MAJOR <br />OBSERVATIONS: The bottom of the pool cannot be seen because of the cloudy water. The water must be cleared up so <br />that the bottom pool drain can be seen. Correct by 2 days. <br />CALCODE DESCRIPTION: Pool operator shall maintain clear pool water while pool is in use or shall close the pool if the bottom of the <br />pool at the maximum depth is not clearly visible from the deck. (CCR 65527) <br /> #22 Skimmer Assembly <br />OBSERVATIONS: Some skimmers are lacking floating weirs and one weir is in backwards. Repair and replace these weirs <br />by 2 days. <br />CALCODE DESCRIPTION: Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br />maintained in accordance with manufacturer specifications. (CBC 3136B) <br /> #35 Flow Meters <br />OBSERVATIONS: The filter system is lacking a flow meter. Install a flow meter on the outlet pipe of the filter. <br />CALCODE DESCRIPTION: Flow meters shall be provided on each recirculation system and shall be installed in accordance with <br />manufacturer's specifications. (CBC 3125B) <br /> #36 Pressure and Vacuum Gauges <br />OBSERVATIONS: The effluent guage is missing. Install an effluent guage on the outlet of the filter. <br />CALCODE DESCRIPTION: Pressure and vacuum gauges shall be provided for each pump system. (CBC 3125B) <br />Page 1 of 2EHD 36-01 Rev. 06/30/15 Swimming Pool OIR <br />FA0002783 PR0360287 SC001 06/14/2022 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjcehd.com