Laserfiche WebLink
Environmental Health Department <br />Time In: <br />11:50 am <br />11:00 am <br />Time Out: <br />Program Element: 3611 - PUBLIC POOL/SPA - PRIMARY <br />Telephone: (209) 957-1688 Owner/Operator: LINC HOUSING <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 4550 SHELLEY CT, STOCKTON 95207 <br />Date: 06/29/2022Name of Facility: PACIFIC VILLAS LP <br />Reinspection on or after: 07/13/2022 <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #10 Disinfectant Residual MAJOR <br />OBSERVATIONS: The free chlorine was 0.8 ppm. Maintain chlorine between 1-10 ppm without cyanuric acid and between <br />2-10 ppm with cyanuric acid when operating. Corrected on site, it was 3.8 ppm. <br />CALCODE DESCRIPTION: Public pools, when open or in use, shall be disinfected continuously by approved chemicals and shall maintain <br />the following concentrations: 1.0 ppm to 10.0 ppm free chlorine without cyanuric acid, 2.0 ppm to 10.0 ppm free chlorine with cyanuric acid <br />or 2.0 ppm bromine. Spas, wading pools, and spray grounds shall maintain the following concentrations: 3.0 ppm to 10.0 ppm free <br />chlorine or 4.0 ppm bromine. (CCR 65529) <br /> #3 Safety Signs <br />OBSERVATIONS: Lacking diarrhea sign on parking lot side gate door. Provide today. <br />Writing on emergency sign has faded. Provide legible information for nearest emergency services and pool facility name <br />and address in at least 1 in. high letter today. <br />Lacking max pool capacity sign and no lifeguard sign inside pool enclosure. Provide signs today. <br />CALCODE DESCRIPTION: Pool operator shall keep safety signs well maintained. (CCR 65535) Safety signs shall have clearly legible <br />letters or numbers not less than 4 inches high, unless otherwise specified. Safety signs shall be affixed to a wall, pole, gate, or similar <br />permanent structure in a location visible to all pool users, unless otherwise specified. (CBC 3120B) <br /> #7 Pool Deck <br />OBSERVATIONS: Observed damaged pool deck around side skimmer. Repair within 2 weeks. <br />Observed gaps between coping and deck. Seal gaps within 2 weeks. <br />CALCODE DESCRIPTION: An unobstructed 4-foot wide deck of concrete or like material shall be provided and maintained flush with the <br />top of the pool coping. Deck shall extend completely around the pool and shall further extend 4 feet on both sides and to the rear of any <br />diving board, ADA device, or slide. (CBC 3114B) Pool operator shall keep the pool deck well maintained. (CCR 65535) <br />Page 1 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0002507 PR0360408 SC001 06/29/2022 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD