Environmental Health Department <br />Time In: <br /> 2:20 pm <br /> 1:20 pm <br />Time Out: <br />Program Element: 3611 - PUBLIC POOL/SPA - PRIMARY <br />Telephone: Owner/Operator: LA ESPANA LLC <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 1141 STRATFORD CIR, STOCKTON 95207 <br />Date: 07/06/2022Name of Facility: LA ESPANA APARTMENTS STOCKTON <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #22 Skimmer Assembly <br />OBSERVATIONS: The skimmer assembly is missing float valve. Provide within one week. <br />CALCODE DESCRIPTION: Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br />maintained in accordance with manufacturer specifications. (CBC 3136B) <br /> #29 Recirculation System Operation <br />OBSERVATIONS: The recirculation system was off. The recirculation system shall be in operation whenever the pool is <br />available for use and additional times as needed to maintain clear pool water. Maintain today. <br />CALCODE DESCRIPTION: Recirculation system shall be in operation whenever the pool is available for use and additional times as <br />needed to maintain clear pool water. (CCR 65525) <br /> #38 Filter Cleaning and Maintenance <br />OBSERVATIONS: The effluent pressure gauge is missing. Provide within one week. <br />CALCODE DESCRIPTION: All filters shall be maintained in accordance with manufacturer's specifications. (CBC 3123B) Pressure gauge <br />located on the filter shall be marked with the clean startup reading. (CBC 3125B) Each filter vessel shall be provided with valves so that it <br />can be isolated from the recirculation system for repairs and backwashing. (CBC 3128B) <br />OVERALL INSPECTION NOTES AND COMMENTS <br />OBSERVATIONS <br />Flow rate:gpm <br />pH: <br />Chlorine:ppm <br />Cyanuric acid:ppm <br />Temp:º F 30 <br />7.4 <br />>10.2 <br /><30 Combined chlorine:ppm <br />NOTES <br />Page 1 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0001264 PR0360378 SC001 07/06/2022 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD