Laserfiche WebLink
S A N J 0 A Q I I I Irl Environmental Health Department <br /> CCUN r <br /> Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> STOCKTON FOOD&GAS#2 2057 S EL DORADO ST, STOCKTON June 29, 2022 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 303 CCR 66262.34(d)(2) Failed to maintain all communication or alarm systems, spill control, or decontamination <br /> equipment. <br /> OBSERVATION: The fire extinguishers located inside the store have not been inspected within the last year. <br /> REGULATION GUIDANCE:All facility communications or alarm systems,fire protection equipment, spill control <br /> equipment, and decontamination equipment,where required, shall be tested and maintained as necessary to assure <br /> its proper operation in time of emergency. <br /> CORRECTIVE ACTION: Bring the fire extinguishers into proper working order by repair, replacement or testing. <br /> Provide a corrective action statement to the San Joaquin County Environmental Health Department within 30 days. <br /> This is a Class II violation. <br /> 403 CCR 66262.34(d)(2) Failed to keep hazardous waste containers closed except when adding or removing hazardous <br /> waste. <br /> OBSERVATION: The following open hazardous waste storage containers were observed on-site: <br /> -One blue 55-gallon plastic drum containing fuel contaminated liquid located on the north side of the store. <br /> REGULATION GUIDANCE:A container holding hazardous waste shall always be closed during transfer and <br /> storage, except when it is necessary to add or remove waste. <br /> CORRECTIVE ACTION: Immediately close these containers and ensure all hazardous waste containers are closed <br /> when not adding or removing waste. Provide a corrective action statement and supporting documentation to the <br /> San Joaquin County Environmental Health Department within 30 days. <br /> This is a Class II violation. <br /> 601 CCR 66262.34(d)Stored hazardous waste onsite greater than 180 days(90 days acute/extremely). <br /> OBSERVATION: The following hazardous waste containers were found on-site with an accumulation start date of <br /> greater than 180 days or no accumulation start date: <br /> -Blue 55-gallon plastic drum containing fuel contaminated liquid had no accumulation start date. <br /> -Black 55-gallon steel drum had no accumulation start date. <br /> REGULATION GUIDANCE: Title 22 California Code of Regulations section 66262.34. <br /> CORRECTIVE ACTION: Immediately dispose of the hazardous waste stored on site greater than 180 days in <br /> compliance with Title 22 California Code of Regulations. Provide a corrective action statement and a copy of the <br /> disposal records to the San Joaquin County Environmental Health Department(EHD)within 30 days. <br /> This is a Class II violation. <br /> FA0003735 PR0521728 SCO01 06/29/2022 <br /> EHD 22-01 Rev.9/16/2020 Page 6 of 7 Small Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />