Laserfiche WebLink
Environmental Health Department <br />Time In: <br /> 9:49 am <br /> 9:02 am <br />Time Out: <br />Program Element: 3611 - PUBLIC POOL/SPA - PRIMARY <br />Telephone: (209) 576-7800 Owner/Operator: LANDMARK PROPERTIES <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 495 CHERRY LN, MANTECA 95337 <br />Date: 06/28/2022Name of Facility: CHERRY LANE OWNERS ASSOCIATION <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #4 Safety Equipment MAJOR <br />OBSERVATIONS: Body hook is not available on site. Provide body hook today. Corrected. <br />CALCODE DESCRIPTION: Safety equipment shall be provided, maintained, readily visible, and available for use. Pools shall have at <br />minimum one 12 foot fixed-length rescue pole with a permanently attached body hook and one 17-inch life ring with an attached throw <br />rope. Throw rope shall be of sufficient length to span the maximum width of the pool and shall be stored to prevent kinking or fouling. <br />(CCR 65540) <br /> #8 Pool and Deck Lighting <br />OBSERVATIONS: Both pool light fixtures are off. Pool operating hours till 7PM and is locked daily so nobody access it after <br />hours. Replace light fixtures in 1 month. <br />CALCODE DESCRIPTION: Pools used at night shall be equipped with underwater light fixtures that provide complete illumination of the <br />pool. When a pool is used at night, pool deck and emergency egress areas shall be provided with lighting. If underwater or deck lighting is <br />not operational, the pool operator shall post a sign in 4-inch letters stating "NO USE OF POOL ALLOWED AFTER DARK" and shall <br />secure the pool area and not permit any use of the pool after dark. (3115B) <br /> #9 Ladders and Handrails <br />OBSERVATIONS: Double hand rail at 8 FT depth is loose. Secure the hand rail in 1 week. <br />CALCODE DESCRIPTION: A means of entry and exit shall be provided at both the shallow and deep end of the pool. Ladders and <br />handrails shall be corrosion resistant and shall be rigidly installed. At least one handrail shall extend from the deck to not less than a point <br />above the top of the lowest step. Handrails shall be installed between 28 to 36 inches above the steps and deck. (CBC 3111B) Pool <br />operator shall keep ladders and handrails well maintained. (CCR 65535) <br /> #17 Cleanliness of Pool <br />OBSERVATIONS: I observe dirt at the bottom of the pool and debris in the water. Clean pool today. <br />CALCODE DESCRIPTION: Pool operator shall maintain clean pool water while the pool is in use and shall not allow debris to accumulate <br />in the pool. Pool operator shall clean the bottom, sides, and other surfaces of the pool as often as necessary to keep pool surfaces clean <br />and free of slime and algae. (CCR 65533) <br />Page 1 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0001268 PR0360258 SC001 06/28/2022 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD