Laserfiche WebLink
Environmental Health Department <br />Time In: <br /> 1:00 pm <br />12:28 pm <br />Time Out: <br />Program Element: 3611 - PUBLIC POOL/SPA - PRIMARY <br />Telephone: (209) 477-3871 Owner/Operator: VENETIAN GARDENS ASSOC <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 1555 MOSAIC WAY, STOCKTON 95207 <br />Date: 06/28/2022Name of Facility: VENETIAN GARDEN HOA REC CENTER <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #5 Restrooms and Showers <br />OBSERVATIONS: The hot water handle in the women's restroom does not work. Repair/replace faucet so it is in good <br />working order. Correct today. <br />CALCODE DESCRIPTION: Pool operator shall ensure the following facilities are maintained and kept clean: showers, toilets, dressing <br />facilities, drinking fountains, diaper-changing stations, floors, walls, partitions, doors, and lockers. Showers (except outside) shall be <br />provided with soap in dispensers. Toilet facilities shall be provided with toilet tissue, hand soap, and paper towels or hot air blowers in <br />permanently installed dispensers. Pool operator shall provide a minimum of one waste receptacle in each toilet facility. Wooden slats, <br />duckboards and footbaths are prohibited. ( CCR 65535, 65551) Showers and lavatories shall be provided with hot and cold water faucets. <br />Maximum water temperature at showers and lavatories shall not exceed 110*F. (CBC 3116B) <br /> #22 Skimmer Assembly <br />OBSERVATIONS: Four weirs were missing from the skimmers. Install/provide all parts to the skimmers. Correct today. <br />(REPEAT) <br />CALCODE DESCRIPTION: Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br />maintained in accordance with manufacturer specifications. (CBC 3136B) <br /> #35 Flow Meters <br />OBSERVATIONS: The flow meter is not functioning. Replace/repair today. <br />CALCODE DESCRIPTION: Flow meters shall be provided on each recirculation system and shall be installed in accordance with <br />manufacturer's specifications. (CBC 3125B) <br />OVERALL INSPECTION NOTES AND COMMENTS <br />OBSERVATIONS <br />Flow rate:gpm <br />pH: <br />Chlorine:ppm <br />Cyanuric acid:ppm <br />Temp:º F <br />7.6 <br />2 <br /><30 Combined chlorine:ppm <br />NOTES <br />Influent 12/0/9 psi <br />Page 1 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0001674 PR0360166 SC001 06/28/2022 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD