Laserfiche WebLink
Environmental Health Department <br />Time In: <br /> 3:10 am <br /> 2:10 am <br />Time Out: <br />Program Element: 3611 - PUBLIC POOL/SPA - PRIMARY <br />Telephone: (209) 478-0318 Owner/Operator: DELTA BAY PROPERTIES <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 1350 BUCKINGHAM WAY, STOCKTON 95207 <br />Date: 06/28/2022Name of Facility: VILLAGE OF THE PINES APTS <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #7 Pool Deck <br />OBSERVATIONS: The wood like material (inserts or divider between concrete)on the concrete deck is not flushed. Repair <br />and maintain today. <br />CALCODE DESCRIPTION: An unobstructed 4-foot wide deck of concrete or like material shall be provided and maintained flush with the <br />top of the pool coping. Deck shall extend completely around the pool and shall further extend 4 feet on both sides and to the rear of any <br />diving board, ADA device, or slide. (CBC 3114B) Pool operator shall keep the pool deck well maintained. (CCR 65535) <br /> #9 Ladders and Handrails <br />OBSERVATIONS: The double and the single handrails are loose. Repair and maintain today. <br />CALCODE DESCRIPTION: A means of entry and exit shall be provided at both the shallow and deep end of the pool. Ladders and <br />handrails shall be corrosion resistant and shall be rigidly installed. At least one handrail shall extend from the deck to not less than a point <br />above the top of the lowest step. Handrails shall be installed between 28 to 36 inches above the steps and deck. (CBC 3111B) Pool <br />operator shall keep ladders and handrails well maintained. (CCR 65535) <br /> #15 Operation Records <br />OBSERVATIONS: The operation records for 2021 and 2022 are missing. Maintain written records of all maintenance and <br />test results for at least two years. Provide today. <br />CALCODE DESCRIPTION: Pool operator shall test the disinfectant residual, pH, and spa water temperature a minimum of once per day. <br />Cyanuric acid concentration shall be tested once per month if cyanuric acid is used. Combined chlorine shall be tested as often as <br />necessary to maintain the concentration below 0.4 ppm. Pool operator shall maintain written records of all maintenance and test results <br />for at least two years and shall submit those records to the enforcement agency upon request. (CCR 65523) <br /> #17 Cleanliness of Pool <br />OBSERVATIONS: The water surface is full of debris. Maintain clean pool today. <br />CALCODE DESCRIPTION: Pool operator shall maintain clean pool water while the pool is in use and shall not allow debris to accumulate <br />in the pool. Pool operator shall clean the bottom, sides, and other surfaces of the pool as often as necessary to keep pool surfaces clean <br />and free of slime and algae. (CCR 65533) <br />Page 1 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0001455 PR0360171 SC001 06/28/2022 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD