Laserfiche WebLink
Environmental Health Department <br />Time In: <br /> 2:45 am <br /> 1:45 am <br />Time Out: <br />Program Element: 3611 - PUBLIC POOL/SPA - PRIMARY <br />Telephone: Owner/Operator: GROUSE RUN APARTMENTS <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 4738 GROUSE RUN DR, STOCKTON 95207 <br />Date: 06/21/2022Name of Facility: GROUSE RUN APARTMENTS <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #1 Pool Gates <br />OBSERVATIONS: The self- closing self- latching devices will not close all the way. Keep gates and doors leading into the <br />pool area well maintained. Adjust or replace today. <br />CALCODE DESCRIPTION: Gates and doors leading into the pool area shall be equipped with self-closing self-latching devices. <br />Self-latching devices shall be designed to keep the gate or door securely closed. Gates and doors shall open outward from the pool area <br />except where otherwise prohibited by law. (CBC 3119B) Pool operator shall keep gates and doors leading into the pool area well <br />maintained. (CCR 65535) <br /> #2 Pool Enclosure <br />OBSERVATIONS: Vertical members of pool (metal post) enclosure are deteriorated. Repair or replace vertical members <br />immediately. <br />CALCODE DESCRIPTION: Pool area shall be enclosed by one or more of the following: a fence, portion of a building, wall, or other <br />approved durable enclosure. Pool enclosure shall be constructed over a hard permanent material equivalent to concrete and shall be <br />installed no more than 2 inches above the finished grade. Holes, gaps, or openings in the enclosure shall not allow the passage of a <br />4-inch diameter sphere. Doors, openable windows, or gates of living quarters shall not be permitted as part of the pool enclosure. (CBC <br />3119B) Pool operator shall keep the pool enclosure well maintained. (CCR 65535) Pool enclosure shall have a minimum effective <br />perpendicular height of 5 feet and shall be constructed so that it cannot be climbed by small children. Horizontal members shall be spaced <br />at least 48 inches apart. No planters or other climbable structures shall be permitted within 5 feet of the pool enclosure or within a 5-foot <br />arc. Chain link openings shall not be larger than 1 3/4 inches when measured horizontally. Pool enclosures with a height of 4 or more feet <br />are allowed if the enclosure was constructed prior to July 1994. (CBC 3119B) <br />Page 1 of 3EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0002603 PR0360050 SC001 06/21/2022 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD