My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2022
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DRIFTWOOD
>
2930
>
3600 - Recreational Health Program
>
PR0360017
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/12/2022 9:03:08 AM
Creation date
7/12/2022 8:59:08 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3600 - Recreational Health Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0360017
PE
3611
FACILITY_ID
FA0002098
FACILITY_NAME
CAVENDISH SQUARE COA
STREET_NUMBER
2930
STREET_NAME
DRIFTWOOD
STREET_TYPE
PL
City
STOCKTON
Zip
95219
APN
11613002
CURRENT_STATUS
01
SITE_LOCATION
2930 DRIFTWOOD PL
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br />Time In: <br />12:00 pm <br />11:00 am <br />Time Out: <br />Program Element: 3611 - PUBLIC POOL/SPA - PRIMARY <br />Telephone: Owner/Operator: KATZAKIAN PROPERTY MGMT LTD <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 2930 DRIFTWOOD PL, STOCKTON 95219 <br />Date: 06/24/2022Name of Facility: CAVENDISH SQUARE COA <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #4 Safety Equipment <br />OBSERVATIONS: The life ring is missing the throw rope. Provide the throw rope today <br />CALCODE DESCRIPTION: Safety equipment shall be provided, maintained, readily visible, and available for use. Pools shall have at <br />minimum one 12 foot fixed-length rescue pole with a permanently attached body hook and one 17-inch life ring with an attached throw <br />rope. Throw rope shall be of sufficient length to span the maximum width of the pool and shall be stored to prevent kinking or fouling. <br />(CCR 65540) <br /> #5 Restrooms and Showers <br />OBSERVATIONS: The Men's restroom is lacking hot water for both sinks. Provide hot water today. <br />CALCODE DESCRIPTION: Pool operator shall ensure the following facilities are maintained and kept clean: showers, toilets, dressing <br />facilities, drinking fountains, diaper-changing stations, floors, walls, partitions, doors, and lockers. Showers (except outside) shall be <br />provided with soap in dispensers. Toilet facilities shall be provided with toilet tissue, hand soap, and paper towels or hot air blowers in <br />permanently installed dispensers. Pool operator shall provide a minimum of one waste receptacle in each toilet facility. Wooden slats, <br />duckboards and footbaths are prohibited. ( CCR 65535, 65551) Showers and lavatories shall be provided with hot and cold water faucets. <br />Maximum water temperature at showers and lavatories shall not exceed 110*F. (CBC 3116B) <br /> #9 Ladders and Handrails <br />OBSERVATIONS: <br />CALCODE DESCRIPTION: A means of entry and exit shall be provided at both the shallow and deep end of the pool. Ladders and <br />handrails shall be corrosion resistant and shall be rigidly installed. At least one handrail shall extend from the deck to not less than a point <br />above the top of the lowest step. Handrails shall be installed between 28 to 36 inches above the steps and deck. (CBC 3111B) Pool <br />operator shall keep ladders and handrails well maintained. (CCR 65535) <br /> #13 Cyanuric Acid Concentration <br />OBSERVATIONS: The cyanuric acid concentration is greater than 100. Maintain cyanuric acid concentration between 0.0 <br />ppm and 100 ppm immediately. <br />CALCODE DESCRIPTION: Pool operator shall maintain cyanuric acid concentration between 0.0 ppm and 100 ppm. (CCR 65530) <br />Page 1 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0002098 PR0360017 SC001 06/24/2022 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD
The URL can be used to link to this page
Your browser does not support the video tag.