Environmental Health Department <br />Time In: <br /> 2:30 pm <br /> 1:30 pm <br />Time Out: <br />Program Element: 3611 - PUBLIC POOL/SPA - PRIMARY <br />Telephone: Owner/Operator: LANDMARK LIMITED LLC <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 6425 HARRISBURG PL, STOCKTON 95207 <br />Date: 07/07/2022Name of Facility: LINCOLN VILLAGE HOMES ASSN #2 <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #9 Ladders and Handrails <br />OBSERVATIONS: The double hand rail is loose. Repair and maintain today. <br />CALCODE DESCRIPTION: A means of entry and exit shall be provided at both the shallow and deep end of the pool. Ladders and <br />handrails shall be corrosion resistant and shall be rigidly installed. At least one handrail shall extend from the deck to not less than a point <br />above the top of the lowest step. Handrails shall be installed between 28 to 36 inches above the steps and deck. (CBC 3111B) Pool <br />operator shall keep ladders and handrails well maintained. (CCR 65535) <br /> #38 Filter Cleaning and Maintenance <br />OBSERVATIONS: The efficient pressure gauge on pump 3 is damaged. Repair/replace within one week. <br />CALCODE DESCRIPTION: All filters shall be maintained in accordance with manufacturer's specifications. (CBC 3123B) Pressure gauge <br />located on the filter shall be marked with the clean startup reading. (CBC 3125B) Each filter vessel shall be provided with valves so that it <br />can be isolated from the recirculation system for repairs and backwashing. (CBC 3128B) <br />OVERALL INSPECTION NOTES AND COMMENTS <br />OBSERVATIONS <br />Flow rate:gpm <br />pH: <br />Chlorine:ppm <br />Cyanuric acid:ppm <br />Temp:º F 230 <br />7.6 <br />6.0 <br /><30 Combined chlorine:ppm <br />NOTES <br />Routine inspection for the pool. The followings were noted. <br />Pump 1: influent 12 psi; effluent 7 psi <br />Pump 2: influent 12 psi; effluent 5 psi <br />Pump 3: influent 15 psi; effluent 12 psi <br />Pump 4: influent 12 psi; effluent 5 psi <br />The effluent pressure gauge on pump 3 is damaged. <br />Pool hour is 1pm - 7pm <br />No underwater pool light. <br />The inspection report was discussed with Amanda Navidad, pool manager. <br />Inspection report will be email to Amanda Navidad. <br />Page 1 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0002408 PR0360489 SC001 07/07/2022 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD