Laserfiche WebLink
SIU I Environmental Health Department <br /> - i CUNTY I <br /> Erectness grows here, Time In: 1025 am <br /> Time Out: 11:10 am <br /> Swimming Pool Official Inspection Report <br /> Name of Facility: SFC LUXE INVESTORS LLC Date: 07/11/2022 <br /> Address: 1641 N RIPON RD, RIPON 95366 <br /> Owner/Operator: SFC LUXE INVESTORS LLC Telephone: <br /> Program Element: 3611 -PUBLIC POOL/SPA-PRIMARY <br /> Inspection Type: ROUTINE INSPECTION -Operating Permit Reinspection on or after: 07/12/2022 <br /> VIOLATIONS AND CORRECTIVE ACTIONS <br /> Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s)116043, 116040,& <br /> 116050. All violations must be corrected within specified timeframe. Violations that are classified as"MAJOR"pose an immediate threat to public health <br /> and must be corrected immediately or be subject to closure pursuant to California Code of Regulations(Title 22)section 65545. <br /> #10 Disinfectant Residual MAJOR <br /> OBSERVATIONS:Free chlorine is 0.2 ppm. Maintenance personnel put chlorine tablets and after 30 minutes,free chlorine <br /> is checked to be still at 0.6ppm. Provide 2ppm- 10ppm today. <br /> CALCODE DESCRIPTION:Public pools, when open or in use,shall be disinfected continuously by approved chemicals and shall maintain <br /> the following concentrations: 1.0 ppm to 10.0 ppm free chlorine without cyanuric acid, 2.0 ppm to 10.0 ppm free chlorine with cyanuric acid <br /> or 2.0 ppm bromine. Spas, wading pools,and spray grounds shall maintain the following concentrations:3.0 ppm to 10.0 ppm free <br /> chlorine or 4.0 ppm bromine. (CCR 65529) <br /> #12 pH Level MAJOR <br /> OBSERVATIONS:pH is at 7. Provide pH 7.2-7.8 today. <br /> CALCODE DESCRIPTION:Pool operator shall maintain pH between 7.2 and 7.8. (CCR 65530) <br /> #9 Ladders and Handrails <br /> OBSERVATIONS:Single hand rail is loose. Secure hand rail in 1 week. <br /> CALCODE DESCRIPTION:A means of entry and exit shall be provided at both the shallow and deep end of the pool.Ladders and <br /> handrails shall be corrosion resistant and shall be rigidly installed.At least one handrail shall extend from the deck to not less than a point <br /> above the top of the lowest step.Handrails shall be installed between 28 to 36 inches above the steps and deck. (CBC 3111 B)Pool <br /> operator shall keep ladders and handrails well maintained. (CCR 65535) <br /> #22 Skimmer Assembly <br /> OBSERVATIONS:Both pool skimmers are lacking weir gates. Provide weir gates today. <br /> One of two skimmers baskets has debris. Clean basket today. <br /> CALCODE DESCRIPTION:Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br /> maintained in accordance with manufacturer specifications. (CBC 31368) <br /> FA0023665 PR0541308 SCO01 07/11/2022 <br /> EHD 36-01 Rev.09/16/2020 Page 1 of 2 Swimming Pool OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />