Laserfiche WebLink
Environmental Health Department <br />Time In: <br /> 9:15 am <br /> 9:00 am <br />Time Out: <br />Program Element: 3611 - PUBLIC POOL/SPA - PRIMARY <br />Telephone: (209) 952-9400 Owner/Operator: STONEWOOD ESTATES HOA <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 2727 SUMMER FIELD DR, STOCKTON 95209 <br />Date: 07/11/2022Name of Facility: STONEWOOD ESTATES HOA <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #4 Safety Equipment <br />OBSERVATIONS: Rope is lacking for the life ring. <br />Provide a rope attached to the life ring that spans a minimum width of the pool. <br />CALCODE DESCRIPTION: Safety equipment shall be provided, maintained, readily visible, and available for use. Pools shall have at <br />minimum one 12 foot fixed-length rescue pole with a permanently attached body hook and one 17-inch life ring with an attached throw <br />rope. Throw rope shall be of sufficient length to span the maximum width of the pool and shall be stored to prevent kinking or fouling. <br />(CCR 65540) <br /> #8 Pool and Deck Lighting <br />OBSERVATIONS: One light is not operative, <br />Provide operative pool light and functional pool GFI. <br />CALCODE DESCRIPTION: Pools used at night shall be equipped with underwater light fixtures that provide complete illumination of the <br />pool. When a pool is used at night, pool deck and emergency egress areas shall be provided with lighting. If underwater or deck lighting is <br />not operational, the pool operator shall post a sign in 4-inch letters stating "NO USE OF POOL ALLOWED AFTER DARK" and shall <br />secure the pool area and not permit any use of the pool after dark. (3115B) <br /> #22 Skimmer Assembly <br />OBSERVATIONS: Two skimmer baskets are cracked. <br />Provide skimmer baskets that are intact. <br />CALCODE DESCRIPTION: Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br />maintained in accordance with manufacturer specifications. (CBC 3136B) <br /> #35 Flow Meters <br />OBSERVATIONS: Flow meter is lacking. <br />(I observed flow meter that will be installed) <br />Provide flow meter by next pool season. <br />CALCODE DESCRIPTION: Flow meters shall be provided on each recirculation system and shall be installed in accordance with <br />manufacturer's specifications. (CBC 3125B) <br />Page 1 of 2EHD 36-01 Rev. 06/30/15 Swimming Pool OIR <br />FA0002066 PR0360459 SC001 07/11/2022 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjcehd.com