Laserfiche WebLink
Environmental Health Department <br />Time In: <br />10:36 am <br />10:06 am <br />Time Out: <br />Program Element: 3611 - PUBLIC POOL/SPA - PRIMARY <br />Telephone: (916) 872-1810 Owner/Operator: FERGUSON & BREWER <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 7565 SHORELINE DR, STOCKTON 95219 <br />Date: 07/14/2022Name of Facility: LAKEVIEW VILLAGE APARTMENTS <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #9 Ladders and Handrails <br />OBSERVATIONS: One handrail was loose on the south side of the deep end of the pool. Secure hand rails. This was <br />corrected on site. <br />CALCODE DESCRIPTION: A means of entry and exit shall be provided at both the shallow and deep end of the pool. Ladders and <br />handrails shall be corrosion resistant and shall be rigidly installed. At least one handrail shall extend from the deck to not less than a point <br />above the top of the lowest step. Handrails shall be installed between 28 to 36 inches above the steps and deck. (CBC 3111B) Pool <br />operator shall keep ladders and handrails well maintained. (CCR 65535) <br /> #22 Skimmer Assembly <br />OBSERVATIONS: The following skimmers were missing parts: <br />-The deep end skimmer was missing both o-rings of the float assembly. <br />-The south shallow end skimmer was missing both o-rings of the float assembly. <br />-The north shallow end skimmer was missing a weir. This was corrected on site. <br />Install/provide all parts to the skimmers. Correct today. <br />CALCODE DESCRIPTION: Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br />maintained in accordance with manufacturer specifications. (CBC 3136B) <br />OVERALL INSPECTION NOTES AND COMMENTS <br />OBSERVATIONS <br />Flow rate:gpm <br />pH: <br />Chlorine:ppm <br />Cyanuric acid:ppm <br />Temp:º F 130 <br />7.2 <br />4 <br /><30 Combined chlorine:ppm <br />NOTES <br />Pool <br />Influent 8 psi <br />Effluent 5 psi <br />Page 1 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0002634 PR0360063 SC001 07/14/2022 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD