Laserfiche WebLink
Environmental Health Department <br />Time In: <br />10:15 am <br /> 9:15 am <br />Time Out: <br />Program Element: 3611 - PUBLIC POOL/SPA - PRIMARY <br />Telephone: (209) 823-4817 Owner/Operator: EASTGATE APARTMENTS <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 167 N SHERIDAN AVE, MANTECA 95336 <br />Date: 07/14/2022Name of Facility: EASTGATE APARTMENTS <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #10 Disinfectant Residual MAJOR <br />OBSERVATIONS: Free chlorine is at 18 ppm. Provide free chlorine 2 ppm - 10 ppm today. Chlorine neutralizer is added <br />then free chlorine is rechecked later. Free chlorine is at 10.4 ppm. Corrected on site. <br />CALCODE DESCRIPTION: Public pools, when open or in use, shall be disinfected continuously by approved chemicals and shall maintain <br />the following concentrations: 1.0 ppm to 10.0 ppm free chlorine without cyanuric acid, 2.0 ppm to 10.0 ppm free chlorine with cyanuric acid <br />or 2.0 ppm bromine. Spas, wading pools, and spray grounds shall maintain the following concentrations: 3.0 ppm to 10.0 ppm free <br />chlorine or 4.0 ppm bromine. (CCR 65529) <br /> #12 pH Level MAJOR <br />OBSERVATIONS: pH is at 8. Provide pH 7.2 -7.8 today. Acid is added to the pool. pH is checked later and it is at 7.8. <br />Corrected on site. <br />CALCODE DESCRIPTION: Pool operator shall maintain pH between 7.2 and 7.8. (CCR 65530) <br /> #9 Ladders and Handrails <br />OBSERVATIONS: Left single handrail is loose. Secure the handrail today. <br />CALCODE DESCRIPTION: A means of entry and exit shall be provided at both the shallow and deep end of the pool. Ladders and <br />handrails shall be corrosion resistant and shall be rigidly installed. At least one handrail shall extend from the deck to not less than a point <br />above the top of the lowest step. Handrails shall be installed between 28 to 36 inches above the steps and deck. (CBC 3111B) Pool <br />operator shall keep ladders and handrails well maintained. (CCR 65535) <br /> #17 Cleanliness of Pool <br />OBSERVATIONS: I observe some dirt at the bottom of the pool. Clean pool today. <br />CALCODE DESCRIPTION: Pool operator shall maintain clean pool water while the pool is in use and shall not allow debris to accumulate <br />in the pool. Pool operator shall clean the bottom, sides, and other surfaces of the pool as often as necessary to keep pool surfaces clean <br />and free of slime and algae. (CCR 65533) <br />Page 1 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0000965 PR0360345 SC001 07/14/2022 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD