San Joaquin General Hospital
STREET_NUMBER
500
Direction
W
STREET_NAME
HOSPITAL
STREET_TYPE
Rd
City
French Camp
Zip
95231
CURRENT_STATUS
01
SITE_LOCATION
500 W Hospital Rd
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
109
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3 . 0 Description of the Test Equipment <br /> The Pneumercator LLP -203 Series PLLD is an electronic line leak detector. The <br /> Pneumercator LLP -203 Series PLLD monitors the pressure of the pipeline . If the <br /> pressure drops quickly enough below the threshold of the Hourly Test , a leak is <br /> declared and an alarm is generated . <br /> 4 . 0 Description of the Testing Location <br /> The Pneumercator LLP -203 Series PLLD was evaluated at the Fuels Management <br /> Research Center located in Grain Valley , Missouri , which is operated by Ken Wilcox <br /> Associates , Inc . Line tests described in this report were conducted on the combination <br /> of pipeline detailed in Table 1 . Table 1 shows the pipeline configuration and product <br /> used , along with the volumes of the line combination . The bulk modulus , which is a <br /> measure of the " stretch " which occurs when the line is pressurized , is shown in <br /> Attachment 3 . Details of the piping configuration used in the evaluation are included in <br /> table 1 . <br /> The conditioned product is contained in a 600 gallon steel tank , which is equipped with <br /> a standard Red Jacket submersible pump . Product is heated or cooled in the tank by <br /> circulating glycol and product through an external heat exchanger . Soil temperatures <br /> were monitored using RTDs , . which were located at 2 inches , 4 inches and 12 inches <br /> from the line as specified by the EPA protocol . A single temperature probe was located <br /> 4 inches from the bottom of the product conditioning tank . The weighted soil <br /> temperature and the product tank temperature at the beginning of the test were used to <br /> compute the temperature differential . <br /> Table 1 . Pi eline Configurations Used for Ho rly Testing <br /> Segment Construction Length Diameter Volume <br /> (ft) ( in ) (gal ) <br /> 1 FRP - single wall 34 3 . 125 13 . 55 <br /> 2 FRP Double wall 200 4 130 . 38 <br /> 3 FRP - single wall 40 3 . 125 16 .45 <br /> 4 Flex -double wall 34 1 . 5 3 . 12 <br /> 5 Flex double wall 130 3 . 125 51 . 8 <br /> 6 FRP - single wall 104 3 . 125 41 .44 <br /> 7 FRP - single wall 27 3 . 125 11 . 1 <br /> 8 NUPI - TSMAXPD 1964 2 321 . 5 <br /> Total 589 . 34 <br /> Maximum Volume Allowable for Pipeline Testing = 1178 . 68 gallons <br /> Bulk Modulus of combination line = 17 , 052 psi <br /> 4 <br />