Laserfiche WebLink
1N JOAQUIN COUN'- <br />ENVIRONMENTAL <br />PROGRAM: RECREATIONAL HL. _LTH <br />PAGE 1 OF 2 <br />POLICY/PROCEDURE: <br />EFFECTIVE DATE: <br />$UPERCEDES: <br />HEALTH <br />DEPARTMENT <br />7-1-2006 <br />06-04 <br />APPROVED 9Y: <br />Donna Heran, REHS, Director <br />TITLE OF POLICY/PROCEDURE: <br />POOL, SPA, and WADING POOL REQUIREMENTS FOR <br />REPLASTERING OR RESURFACING <br />POLICY <br />Prior to replastering or resurfacing any public pool, spa, or wade pool, the San Joaquin County <br />Environmental Health Department (EHD) requires that the pool be inspected to verify <br />compliance with the California Health and Safety Code and the California Code of Regulations. <br />The purpose of this inspection is to identify any structural repairs/retrofits and/or installation of <br />safety devices that must be completed prior to re -opening the pool. <br />PROCEDURE <br />A. An application for a Consultation Inspection must be submitted to the EHD, along with the .� <br />applicable fee, at least 48 hours prior to the inspection. <br />B. The inspection must be done before the replastering or resurfacing is performed, preferably <br />when the pool is empty and sandblasted. <br />C. Compliance with all of the following requirements, where applicable, must be verified by <br />EHD staff prior to application of the plaster or resurfacing material. <br />1. For spa pools that do not have split suction lines for the circulation and booster pump, the <br />suction lines must be split and have a tee connection with a three-foot separation between <br />grates, to reduce the hazard of a suction entrapment. Approved anti -vortex main drain <br />covers are required on all split suction lines. <br />2. For pools that are six -feet deep or less, the main drain shall be split and have a tee <br />connection with a three-foot separation between grates to reduce the hazard of a suction <br />entrapment. <br />3. For spa pools with one skimmer, the equalizer line shall be split and have a tee <br />connection with a three-foot separation between suction lines. They shall also be fitted <br />with approved anti -hair entanglement covers. <br />4. All skimmers with equalizer lines must be fitted with approved anti -hair entanglement <br />type grates. See item #5 for rating requirements. <br />5. Any public pool, spa, or wade pool must have approved -type anti -vortex main drain <br />covers and anti -hair entanglement equalizer line covers installed. The suction fittings <br />shall be ANSUASME Al 12.19.8M rated with a maximum GPM flow imprinted on the <br />fitting. <br />Hand railing must be provided over all stairs, extending from the deck to the bottom step <br />tread. The upper railing surface shall not be less than28 inches nor more than 36 inches <br />above the deck and each step tread. <br />