Laserfiche WebLink
r I Environmental Health Department <br /> SANJOAQU <br /> CUBIT <br /> GreotrrB55 grows here Time In: 1120 am <br /> Time Out: 11:56 am <br /> Swimming Pool Official Inspection Report <br /> Name of Facility: VILLAGIO APARTMENTS Date: 07/21/2022 <br /> Address: 550 SANDY LN, RIPON 95366 <br /> Owner/Operator: FPI MANAGEMENT Telephone: <br /> Program Element: 3611 -PUBLIC POOL/SPA-PRIMARY <br /> Inspection Type: ROUTINE INSPECTION -Operating Permit <br /> VIOLATIONS AND CORRECTIVE ACTIONS <br /> Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s)116043, 116040,& <br /> 116050. All violations must be corrected within specified timeframe. Violations that are classified as"MAJOR"pose an immediate threat to public health <br /> and must be corrected immediately or be subject to closure pursuant to California Code of Regulations(Title 22)section 65545. <br /> #10 Disinfectant Residual MAJOR <br /> OBSERVATIONS:Free chlorine is 20 ppm. Provide free chlorine 2ppm- 10 ppm today. <br /> CALCODE DESCRIPTION:Public pools, when open or in use,shall be disinfected continuously by approved chemicals and shall maintain <br /> the following concentrations: 1.0 ppm to 10.0 ppm free chlorine without cyanuric acid, 2.0 ppm to 10.0 ppm free chlorine with cyanuric acid <br /> or 2.0 ppm bromine. Spas, wading pools,and spray grounds shall maintain the following concentrations:3.0 ppm to 10.0 ppm free <br /> chlorine or 4.0 ppm bromine. (CCR 65529) <br /> #13 Cyanuric Acid Concentration MAJOR <br /> OBSERVATIONS:Cyanuric acid is more than 100 ppm. Provide 0 ppm- 100 ppm at the end of the season. <br /> CALCODE DESCRIPTION:Pool operator shall maintain cyanuric acid concentration between 0.0 ppm and 100 ppm. (CCR 65530) <br /> #8 Pool and Deck Lighting <br /> OBSERVATIONS:Light fixture is not working. Replace light fixture in 1 week. Meanwhile post" NO SWIMMING AFTER <br /> DARK"till repair. <br /> CALCODE DESCRIPTION:Pools used at night shall be equipped with underwater light fixtures that provide complete illumination of the <br /> pool. When a pool is used at night,pool deck and emergency egress areas shall be provided with lighting. If underwater or deck lighting is <br /> not operational, the pool operator shall post a sign in 4-inch letters stating"NO USE OF POOL ALLOWED AFTER DARK"and shall <br /> secure the pool area and not permit any use of the pool after dark. (31156) <br /> #19 Depth Markers <br /> OBSERVATIONS:Depth markers around the pool deck, at 5FT and 3 FT depth, are fading. Provide clear markers in 1 <br /> week. <br /> CALCODE DESCRIPTION:Depth markers shall be clearly marked in the following locations:at maximum depth, at minimum depth, at <br /> each end, on both sides at each end, at the slope break, and along the perimeter of the pool at distances not to exceed 25 feet. Depth <br /> markers shall be 4 inches high in a contrasting color and be marked in units of feet and inches.For pool water depths 6 feet and <br /> shallower,markers with universal"NO DIVING"symbol shall be installed on the deck directly adjacent to the depth markers. (CBC 31 10B) <br /> FA0019002 PR0528055 SCO01 07/21/2022 <br /> EHD 36-01 Rev.09/16/2020 Page 1 of 2 Swimming Pool OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />