Laserfiche WebLink
S A N J O a Q U I N Environmental Health Department <br /> — C 0 j :V y <br /> Swimming Pool Official Inspection Report <br /> Facility Name and Address: SHADOW LAKE MOBILE HOME PARK LLC, 5100 N HWY 99 , STOCKTON 95212 <br /> #7 Pool Deck <br /> OBSERVATIONS:Observed vegetation on southwest corner of pool deck. Clear vegetation within 1 week. <br /> Observed gaps/cracks in pool deck on east side of pool. Repair/resurface pool deck within 2 weeks. <br /> CALCODE DESCRIPTION:An unobstructed 4-foot wide deck of concrete or like material shall be provided and maintained flush with the <br /> top of the pool coping. Deck shall extend completely around the pool and shall further extend 4 feet on both sides and to the rear of any <br /> diving board,ADA device, or slide. (CBC 3114B)Pool operator shall keep the pool deck well maintained. (CCR 65535) <br /> #22 Skimmer Assembly <br /> OBSERVATIONS:Northwest skimmer lid was damaged. Replace skimmer lid. Corrected on site. <br /> Both west skimmers were lacking o-rings. Provide o-rings within 1 week. <br /> CALCODE DESCRIPTION:Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br /> maintained in accordance with manufacturer specifications. (CBC 31368) <br /> #31 Disinfectant Feeders <br /> OBSERVATIONS:Observed chlorine tabs in both west skimmer baskets. Remove tabs from skimmer baskets and use <br /> automatic chlorinator. Corrected on site, tabs were removed. <br /> CALCODE DESCRIPTION:Each pool shall be provided with a system capable of continuous disinfection of the pool water. (CBC 31238) <br /> Disinfectant feeders shall be capable of supplying not less than the equivalent of 3 pounds of 100 percent available chlorine per day per <br /> 10,000 gallons of pool water. (CBC 3134B) <br /> #35 Flow Meters <br /> OBSERVATIONS:The flow meter was stuck. Provide working flow meter today. <br /> CALCODE DESCRIPTION:Flow meters shall be provided on each recirculation system and shall be installed in accordance with <br /> manufacturer's specifications. (CBC 31258) <br /> #38 Filter Cleaning and Maintenance <br /> OBSERVATIONS:The influent and effluent pressure difference was greater than 10 PSI. Clean/backwash filter today. <br /> CALCODE DESCRIPTION:All filters shall be maintained in accordance with manufacturer's specifications. (CBC 31238)Pressure gauge <br /> located on the filter shall be marked with the clean startup reading. (CBC 3125B)Each filter vessel shall be provided with valves so that it <br /> can be isolated from the recirculation system for repairs and backwashing. (CBC 31288) <br /> FA0002794 PR0360256 SCO01 08/03/2022 <br /> EHD 36-01 Rev.09/16/2020 Page 2 of 3 Swimming Pool OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />