Laserfiche WebLink
Environmental Health Department <br />Time In: <br />10:24 am <br /> 9:35 am <br />Time Out: <br />Program Element: 3611 - PUBLIC POOL/SPA - PRIMARY <br />Telephone: (209) 599-8999 Owner/Operator: JAMNADAS, ASHIK <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 1524 COLONY RD, RIPON 95366 <br />Date: 08/03/2022Name of Facility: LA QUINTA RIPON <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #3 Safety Signs <br />OBSERVATIONS: Pool capacity and address signs are fading. Redo the signs today. <br />CALCODE DESCRIPTION: Pool operator shall keep safety signs well maintained. (CCR 65535) Safety signs shall have clearly legible <br />letters or numbers not less than 4 inches high, unless otherwise specified. Safety signs shall be affixed to a wall, pole, gate, or similar <br />permanent structure in a location visible to all pool users, unless otherwise specified. (CBC 3120B) <br /> #4 Safety Equipment <br />OBSERVATIONS: Pool life ring is lacking rope. Provide rope; at least the maximum width of the pool; today. Corrected on <br />site. <br />CALCODE DESCRIPTION: Safety equipment shall be provided, maintained, readily visible, and available for use. Pools shall have at <br />minimum one 12 foot fixed-length rescue pole with a permanently attached body hook and one 17-inch life ring with an attached throw <br />rope. Throw rope shall be of sufficient length to span the maximum width of the pool and shall be stored to prevent kinking or fouling. <br />(CCR 65540) <br /> #7 Pool Deck <br />OBSERVATIONS: I observe some cracks and broken concrete, around the pool double handrail. Repair floor in 2 weeks. <br />CALCODE DESCRIPTION: An unobstructed 4-foot wide deck of concrete or like material shall be provided and maintained flush with the <br />top of the pool coping. Deck shall extend completely around the pool and shall further extend 4 feet on both sides and to the rear of any <br />diving board, ADA device, or slide. (CBC 3114B) Pool operator shall keep the pool deck well maintained. (CCR 65535) <br /> #22 Skimmer Assembly <br />OBSERVATIONS: Pool skimmers are lacking float valves and one skimmer has dislocated weir gate and other skimmer is <br />lacking one. Provide float valves and weir gates today. Corrected on site. <br />CALCODE DESCRIPTION: Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br />maintained in accordance with manufacturer specifications. (CBC 3136B) <br />Page 1 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0017607 PR0526012 SC001 08/03/2022 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD