My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2022
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
2758
>
2300 - Underground Storage Tank Program
>
PR0541416
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/30/2022 8:01:41 AM
Creation date
8/5/2022 10:12:50 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0541416
PE
2351
FACILITY_ID
FA0023733
FACILITY_NAME
Sunwest Chevron
STREET_NUMBER
2758
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
Ln
City
Lodi
Zip
95242
APN
16646031
CURRENT_STATUS
01
SITE_LOCATION
2758 W Kettleman Ln
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
50
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The following is an itemized list of underground storage tank violations that have not <br /> been addressed for Sunwest Chevron as of August 16 , 2022 . <br /> Open violations from October 13 , 2021 inspection <br /> Violation #106 - Failure to submit and maintain a current facility plot plan / site map . <br /> OBSERVATION An accurate UST Monitoring Site Plan was not submitted , the site map is missing the following : <br /> -Sensors monitoring tank annular spaces <br /> - Fill and STP sumps , as well as monitoring in sumps <br /> REGULATION GUIDANCE: A site plan must be submitted identifying the locations where monitoring will be <br /> performed. The site plan must show the general layout of tanks and clearly identify locations of the following <br /> equipment, if installed : 1 ) monitoring panels ; 2 ) in -tank liquid level probes ( if used for leak detection ) ; 3 ) devices <br /> monitoring tank annular spaces or vault; 4 ) devices monitoring product piping ; 5) devices monitoring fill piping ; 6 ) <br /> devices monitoring vent piping ; 7) devices monitoring vapor recovery piping ; 8 ) devices monitoring vent/transition <br /> sumps ; 9 ) devices monitoring under-dispenser containment; 10 ) line leak detectors ; and 11 ) devices monitoring any <br /> other secondary containment areas . <br /> CORRECTIVE ACTION : Immediately log into the California Environmental Reporting System ( CERS ) at <br /> http : //cers. calepa . ca . gov/ and upload a copy of the UST Monitoring Site Plan . <br /> ❑ This violation was corrected ❑ This violation will be corrected by ( date) : <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation : <br /> Violation #107 - Failure to submit and maintain complete and current financial responsibility documents . <br /> 1 ) OBSERVATION Financial responsibility documents have not been submitted to the EHD . Section B was left <br /> blank on the Certification of Financial Responsibility. <br /> REGULATION GUIDANCE: Current financial responsibility documents are required to be submitted annually. <br /> CORRECTIVE ACTION : Immediately log into the California Environmental Reporting System ( CERS) at <br /> http : //cers . calepa . ca . gov/, and upload the required documents . <br /> 2 ) OBSERVATION Current financial responsibility documents were not found on site . <br /> REGULATION GUIDANCE: A copy of current financial responsibility documents are required to be maintained on <br /> site . <br /> CORRECTIVE ACTION : Immediately obtain a copy of the facility's financial responsibility documents and maintain a <br /> copy on site . <br /> i <br /> 4 <br /> Page 1 of 3 <br /> I <br />
The URL can be used to link to this page
Your browser does not support the video tag.