Laserfiche WebLink
SAN 10 A Q U I N Environmental Health Department <br /> -= t Time lm 11-1a am <br /> Time Out: 11:45 am <br /> Swimming Pool Official Inspection Report <br /> Name of Facility: MERIDIAN POINTE Date: 08/15/2019 <br /> Address: 819 E HAMMER LN, STOCKTON 95210 <br /> Owner/Operator: STOCKTON PHOENIX LIMITED Telephone: (209)957-5844 <br /> Program Element: 3612-PUBLIC POOL/SPA-ADDITIONAL <br /> Inspection Type: ROUTINE INSPECTION-Operating Permit <br /> VIOLATIONS AND CORRECTIVE ACTIONS <br /> Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code seotion(s)116043, 116040,& <br /> 116050. All violations must be corrected within specified timeframe. Violations that are classified as'MAJOR"pose an immediate threat to public health <br /> and must be corrected immediately or be subject to closure pursuant to California Code of Regulations(Title 22)section 65545. <br /> Laddersiand Handrail# <br /> OBSERVATIONS:Handrail for the stairs was dislodged from one of its connections. Keep all handrails sturdy and secure. <br /> CALCODE DESCRIPTION:A means of entry and exit shall be provided at both the shallow and deep end of the pool.Ladders and <br /> handrails shall be corrosion resistant and shall be rigidly installed.At least one handrail shall extend from the deck to not less than a point <br /> above the top of the lowest step.Handrails shall be installed between 28 to 35 inches above the steps and deck.(CBC 3111 B)Pool <br /> operator shall keep ladders and handrails well maintained. (CCR 65535) <br /> #13 Cyanuric Acid Concentration <br /> OBSERVATIONS:Cyanuric acid (CYA)concentration was observed to be greater the 100ppm. Keep CYA levels below <br /> 100ppm. <br /> CALCODE DESCRIPTION:Pool operator shall maintain cyanunc acid concentration between 0.0 ppm and 100 ppm. (CCR 65530) <br /> #38 Filter Cleaning and Maintenance <br /> OBSERVATIONS:Pressure differences between the influent and effluent gages possibly indicate a filter in need of cleaning <br /> and maintenance. <br /> CALCODE DESCRIPTION:All fitters shall be maintained in accordance with manufacturers specifications.(CBC 31238)Pressure gauge <br /> located on the fitter shall be marked with the clean startup reading. (CBC 31258)Each filter vessel shall be provided with valves so that it <br /> can be isolated from the recirculation system for repairs and backwashing.(CBC 31288) <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> OBSERVATIONS <br /> Flow rate: 60 gpm Chlorine: 8.6 ppm Temp: °F <br /> Cyanuric acid: >100 ppm pH: 7.2 Combined chlorine: 0.0 ppm <br /> NOTES <br /> Influent-21 psi <br /> Effluent-7psi <br /> Report sent via email to Ramon Santos, Maintenance Supervisor. <br /> FAOM2729 PR0360264 SC001 0811512019 <br /> 11111[136-01 Rev.06/30/15 Page 1 of 2 Swimming Pool OR <br /> 1868 E. Hazelton Avenue I Stockton, California 952051 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />