Environmental Health Department <br />Facility Name and Address: CALIFORNIA INN, 4100 E WATERLOO RD, STOCKTON 95215 <br />Swimming Pool Official Inspection Report <br /> #17 Cleanliness of Pool <br />OBSERVATIONS: Observed black algae growth on sides and bottom on pool. Keep pool surfaces clean and free of slime <br />and algae. <br />CALCODE DESCRIPTION: Pool operator shall maintain clean pool water while the pool is in use and shall not allow debris to accumulate <br />in the pool. Pool operator shall clean the bottom, sides, and other surfaces of the pool as often as necessary to keep pool surfaces clean <br />and free of slime and algae. (CCR 65533) <br /> #22 Skimmer Assembly <br />OBSERVATIONS: Observed excessive debris in skimmer baskets. Clean today and maintain clean. <br />The weir doors for both skimmers came of sides and were in the baskets. Install/replace weir doors within 1 week. <br />CALCODE DESCRIPTION: Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br />maintained in accordance with manufacturer specifications. (CBC 3136B) <br /> #31 Disinfectant Feeders <br />OBSERVATIONS: The automatic chlorinator was disconnected, observed chlorine tablets in skimmer baskets. Discontinue <br />placing tabs in skimmer basket and use automatic chlorinator. Correct today. <br />CALCODE DESCRIPTION: Each pool shall be provided with a system capable of continuous disinfection of the pool water. (CBC 3123B) <br />Disinfectant feeders shall be capable of supplying not less than the equivalent of 3 pounds of 100 percent available chlorine per day per <br />10,000 gallons of pool water. (CBC 3134B) <br /> #35 Flow Meters <br />OBSERVATIONS: The flow meter was stuck. Provide working flow meter today. <br />CALCODE DESCRIPTION: Flow meters shall be provided on each recirculation system and shall be installed in accordance with <br />manufacturer's specifications. (CBC 3125B) <br /> #38 Filter Cleaning and Maintenance <br />OBSERVATIONS: The influent and effluent pressure difference was greater than 10 PSI. Clean/backwash filter today. <br />CALCODE DESCRIPTION: All filters shall be maintained in accordance with manufacturer's specifications. (CBC 3123B) Pressure gauge <br />located on the filter shall be marked with the clean startup reading. (CBC 3125B) Each filter vessel shall be provided with valves so that it <br />can be isolated from the recirculation system for repairs and backwashing. (CBC 3128B) <br />Page 2 of 3EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0002128 PR0360089 SC001 08/10/2022 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD