My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2022
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
1420
>
2300 - Underground Storage Tank Program
>
PR0231736
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/12/2023 11:27:50 AM
Creation date
8/15/2022 8:30:42 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0231736
PE
2361
FACILITY_ID
FA0002562
FACILITY_NAME
Sutter Valley Hospitals dba Sutter Tracy Community Hospital
STREET_NUMBER
1420
Direction
N
STREET_NAME
TRACY
STREET_TYPE
Blvd
City
Tracy
Zip
95376
APN
233-081-01
CURRENT_STATUS
01
SITE_LOCATION
1420 N Tracy Blvd
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
46
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Overfill Protection Testing Testing Procedure <br />25 <br />c. Print the Tank Inventory Report. <br />d. Test the relay assigned to the external Overfill alarm (if present) to insure the Overfill alarm works. <br />1. If the Overfill alarm does not sound, repair the device before continuing testing. <br />Testing <br />ATurn off power to the console. <br />BDisconnect the probe from the field wiring and remove it from the riser. <br />If you are testing more than one tank remove all the probes from their risers. <br />CLay the probe safely on the ground and reattach the field wiring. <br />DPosition the water float at the bottom of the probe and the product float 25% up from the bottom of the <br />probe. <br />EPower the console back on. <br />FSimulate a delivery as follows: <br />Move the float towards the top of the probe at a rate of 1-2” per ten seconds. <br />Continue moving the float to the top of the probe at a rate of 1-2” per ten seconds for the next 50 <br />seconds, the probe is noW in delivery mode. <br />Slide the float at a moderate speed to the top of the probe. Note to not slam the float against the head <br />of the probe, this can damage the float. <br />GOnce the float reaches the overfill level the Overfill alarm, including external Overfill alarm (if present), will <br />sound. <br />HSilence the Overfill alarm on the TLS and external Overfill alarm (if present) by acknowledging it. <br />IMove the float down to the bottom of the probe. The TLS will clear the Overfill alarm once the delivery delay <br />time is complete. <br />JRepeat 3f - 3i for the other probes. <br />Test Completion <br />APrint out the delivery report for all tanks tested. <br />BPower off the console. <br />CReplace the probes back into the tank; before inserting into riser, ensure that the floats are positioned at the <br />bottom of the probe. <br />DPower on the console. <br />EIf the console is running BIR enter a manual adjustment for the amount of the delivery. <br />FIf the site is not running BIR give the delivery report to the store manager so they can log the delivery as <br />part of the overfill testing.