Environmental Health Department <br />Time In: <br />12:30 pm <br />11:50 am <br />Time Out: <br />Program Element: 3611 - PUBLIC POOL/SPA - PRIMARY <br />Telephone: (209) 339-8300 Owner/Operator: GILL, JASBIR FAMILY LMTD PRTSP <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 6120 W BANNER ST, LODI 95242 <br />Date: 06/30/2022Name of Facility: FLAG CITY RV RESORT <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #8 Pool and Deck Lighting <br />OBSERVATIONS: Light at shallow end is not operative. <br />Provide operative light and functional GFI. <br />CALCODE DESCRIPTION: Pools used at night shall be equipped with underwater light fixtures that provide complete illumination of the <br />pool. When a pool is used at night, pool deck and emergency egress areas shall be provided with lighting. If underwater or deck lighting is <br />not operational, the pool operator shall post a sign in 4-inch letters stating "NO USE OF POOL ALLOWED AFTER DARK" and shall <br />secure the pool area and not permit any use of the pool after dark. (3115B) <br /> #9 Ladders and Handrails <br />OBSERVATIONS: Handrail is loose at deep end. <br />Tighten <br />CALCODE DESCRIPTION: A means of entry and exit shall be provided at both the shallow and deep end of the pool. Ladders and <br />handrails shall be corrosion resistant and shall be rigidly installed. At least one handrail shall extend from the deck to not less than a point <br />above the top of the lowest step. Handrails shall be installed between 28 to 36 inches above the steps and deck. (CBC 3111B) Pool <br />operator shall keep ladders and handrails well maintained. (CCR 65535) <br /> #13 Cyanuric Acid Concentration <br />OBSERVATIONS: Cyanuric acid is greater than 100ppm. <br />Provide at 100ppm or less. <br />CALCODE DESCRIPTION: Pool operator shall maintain cyanuric acid concentration between 0.0 ppm and 100 ppm. (CCR 65530) <br /> #18 Pool Shell and Tile <br />OBSERVATIONS: Slight chipping observed on pool shell near steps. <br />Provide so smooth. <br />CALCODE DESCRIPTION: Pool shells shall be white and have a smooth waterproof interior finish that will withstand repeated brushing, <br />and scrubbing. A spa pool may be finished in a light color other than white when approved by the enforcement agency. (CBC 3108B) <br />Page 1 of 2EHD 36-01 Rev. 06/30/15 Swimming Pool OIR <br />FA0016673 PR0524854 SC001 06/30/2022 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjcehd.com