Laserfiche WebLink
Environmental Health Department <br />Time In: <br /> 9:30 am <br /> 8:58 am <br />Time Out: <br />Program Element: 3616 - PUBLIC POOL/SPA - EXEMPT <br />Telephone: (209) 954-5151 Owner/Operator: SAN JOAQUIN DELTA COLLEGE <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 5151 PACIFIC AVE, STOCKTON 95207 <br />Date: 08/09/2022Name of Facility: SAN JOAQUIN DELTA COLLEGE DIST <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #8 Pool and Deck Lighting <br />OBSERVATIONS: Three lights were observed non-operational. Repair/replace lights so that they are in good working order <br />within two weeks. <br />CALCODE DESCRIPTION: Pools used at night shall be equipped with underwater light fixtures that provide complete illumination of the <br />pool. When a pool is used at night, pool deck and emergency egress areas shall be provided with lighting. If underwater or deck lighting is <br />not operational, the pool operator shall post a sign in 4-inch letters stating "NO USE OF POOL ALLOWED AFTER DARK" and shall <br />secure the pool area and not permit any use of the pool after dark. (3115B) <br /> #9 Ladders and Handrails <br />OBSERVATIONS: All handrails were observed loose except the southeast corner. Tighten rails within one week. <br />CALCODE DESCRIPTION: A means of entry and exit shall be provided at both the shallow and deep end of the pool. Ladders and <br />handrails shall be corrosion resistant and shall be rigidly installed. At least one handrail shall extend from the deck to not less than a point <br />above the top of the lowest step. Handrails shall be installed between 28 to 36 inches above the steps and deck. (CBC 3111B) Pool <br />operator shall keep ladders and handrails well maintained. (CCR 65535) <br />OVERALL INSPECTION NOTES AND COMMENTS <br />OBSERVATIONS <br />Flow rate:gpm <br />pH: <br />Chlorine:ppm <br />Cyanuric acid:ppm <br />Temp:º F 1,103 <br />7.8 <br />1.6 <br />0 Combined chlorine:ppm <br />NOTES <br />Influent 18 psi <br />Effluent 14 psi <br />The person in charge is responsible for ensuring that the above mentioned facility is in compliance with all applicable sections of the California Health and <br />Safety Code. If a reinspection is required, fees will be assessed at the current hourly rate. <br />Received by: Name and Title: <br />EH Specialist:Phone:(209) 616-3046 <br />, <br />LYDIA BAKER <br />Page 1 of 1EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0002836 PR0360033 SC001 08/09/2022 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD