My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2022
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BELMONT
>
6401
>
3600 - Recreational Health Program
>
PR0360391
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/15/2022 1:39:22 PM
Creation date
8/15/2022 1:36:39 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3600 - Recreational Health Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0360391
PE
3611
FACILITY_ID
FA0002422
FACILITY_NAME
LINCOLN VILLAGE HOA #3
STREET_NUMBER
6401
STREET_NAME
BELMONT
STREET_TYPE
PL
City
STOCKTON
Zip
95207
APN
09707012
CURRENT_STATUS
01
SITE_LOCATION
6401 BELMONT PL
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br />Time In: <br /> 9:28 am <br /> 8:58 am <br />Time Out: <br />Program Element: 3611 - PUBLIC POOL/SPA - PRIMARY <br />Telephone: (916) 746-0011 Owner/Operator: LINCOLN VILLAGE HOA #3 <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 6401 BELMONT PL, STOCKTON 95207 <br />Date: 08/15/2022Name of Facility: LINCOLN VILLAGE HOA #3 <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #3 Safety Signs <br />OBSERVATIONS: The diarrhea sign was not affixed and was on the ground leaning against the wall. The pool capacity <br />was lacking on the safety sign. Post the diarrhea sign and fill in pool capacity. Correct today. <br />CALCODE DESCRIPTION: Pool operator shall keep safety signs well maintained. (CCR 65535) Safety signs shall have clearly legible <br />letters or numbers not less than 4 inches high, unless otherwise specified. Safety signs shall be affixed to a wall, pole, gate, or similar <br />permanent structure in a location visible to all pool users, unless otherwise specified. (CBC 3120B) <br /> #8 Pool and Deck Lighting <br />OBSERVATIONS: Unable to verify if pool lights are operational. Verify pool lights are in good working order and <br />replace/repair any lights if necessary. Correct within two weeks. <br />CALCODE DESCRIPTION: Pools used at night shall be equipped with underwater light fixtures that provide complete illumination of the <br />pool. When a pool is used at night, pool deck and emergency egress areas shall be provided with lighting. If underwater or deck lighting is <br />not operational, the pool operator shall post a sign in 4-inch letters stating "NO USE OF POOL ALLOWED AFTER DARK" and shall <br />secure the pool area and not permit any use of the pool after dark. (3115B) <br /> #22 Skimmer Assembly <br />OBSERVATIONS: The following was lacking from the skimmers: <br />-north skimmer lacking weir <br />-three skimmers lacking o-rings <br />-one skimmer has o-ring but it is floating in skimmer <br />Provide all parts to the skimmers within two weeks. <br />CALCODE DESCRIPTION: Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br />maintained in accordance with manufacturer specifications. (CBC 3136B) <br /> #35 Flow Meters <br />OBSERVATIONS: The flow meter is not operational. Repair/replace flow meter within two weeks. (REPEAT) <br />CALCODE DESCRIPTION: Flow meters shall be provided on each recirculation system and shall be installed in accordance with <br />manufacturer's specifications. (CBC 3125B) <br />Page 1 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0002422 PR0360391 SC001 08/15/2022 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD
The URL can be used to link to this page
Your browser does not support the video tag.