Laserfiche WebLink
S A N J 0 A Q I I I Irl Environmental Health Department <br /> CCUN r <br /> Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> JAS EXPRESS INC. 1 1415 W ANDERSON ST, STOCKTON August 15, 2022 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 113 HSC 25160.2(b)(3) Failed to keep copies of consolidated manifesting receipts for three years. <br /> OBSERVATION: The business operator could not provide hazardous waste disposal records for the past three <br /> years during the inspection for the following wastes: <br /> -Used absorbent <br /> -Used paper oil filters <br /> REGULATION GUIDANCE: The generator shall retain each consolidated manifest receipt for at least three years. <br /> This period of retention is extended automatically during the course of any unresolved enforcement action regarding <br /> the regulated activity or as requested by the department or a certified unified program agency. <br /> CORRECTIVE ACTION: Provide a copy of disposal records for the past three years 2019-2022 for all hazardous <br /> waste including used absorbent and used paper oil filters. Provide these records and a corrective action statement <br /> to the EHD within 30 days. <br /> This is a Class II violation. <br /> 115 CCR 66266.81(a)(4)(B)Failed to retain copy of manifest or bill of lading for spent lead acid batteries for 3 years. <br /> OBSERVATION: Bills of lading for the recycling of lead acid batteries from 2019-2022 were not found on site. <br /> REGULATION GUIDANCE: <br /> Title 22 California Code of Regulations(CCR)66266.81 Requirements <br /> Title 13 CCR 1161 Shipping Papers <br /> Title 49 Code of Federal Regulations(CFR) Part 172, Subpart C and 49 CFR 177.817 <br /> CORRECTIVE ACTION: Provide copies of battery core bill of lading records and a corrective action statement to <br /> the San Joaquin County Environmental Health Department within 30 days. <br /> This is a Class II violation. <br /> 303 CCR 66262.34(d)(2) Failed to maintain all communication or alarm systems, spill control, or decontamination <br /> equipment. <br /> OBSERVATION:A fire extinguisher located inside of the shop was not charged. <br /> REGULATION GUIDANCE:All facility communications or alarm systems,fire protection equipment,spill control <br /> equipment, and decontamination equipment,where required, shall be tested and maintained as necessary to assure <br /> its proper operation in time of emergency. <br /> CORRECTIVE ACTION: Bring the fire extinguisher into proper working order by repair, replacement or testing. <br /> Provide a corrective action statement to the San Joaquin County Environmental Health Department within 30 days. <br /> This is a Class II violation. <br /> FA0009455 PR0513849 SCO01 08/15/2022 <br /> EHD 22-01 Rev.9/16/2020 Page 5 of 8 Small Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />