SAN <br /> 1` ` e J O 1a Q U I N Environmental Health Department <br /> C 0 U A i `l <br /> Swimming Pool Official Inspection Report <br /> Facility Name and Address: ARBOR MOBILE HOME PARK, 19690 N HWY 99 ,ACAMPO 95220 <br /> #13 Cyanuric Acid Concentration <br /> OBSERVATIONS:The cyanuric acid concentration was greater than 100 ppm. Maintain cyanuric acid between 0-100 ppm <br /> when operating. <br /> CALCODE DESCRIPTION:Pool operator shall maintain cyanuric acid concentration between 0.0 ppm and 100 ppm. (CCR 65530) <br /> #15 Operation Records <br /> OBSERVATIONS:The pool operation records were lacking free chlorine and cyanuric acid testing.Test free chlorine daily <br /> and cyanuric acid at least once a month at pool when operating. <br /> CALCODE DESCRIPTION:Pool operator shall test the disinfectant residual,pH, and spa water temperature a minimum of once per day. <br /> Cyanuric acid concentration shall be tested once per month if cyanuric acid is used. Combined chlorine shall be tested as often as <br /> necessary to maintain the concentration below 0.4 ppm. Pool operator shall maintain written records of all maintenance and test results <br /> for at least two years and shall submit those records to the enforcement agency upon request. (CCR 65523) <br /> #17 Cleanliness of Pool <br /> OBSERVATIONS:Observed debris on bottom of pool at deep end. Keep pool surfaces clean. <br /> CALCODE DESCRIPTION:Pool operator shall maintain clean pool water while the pool is in use and shall not allow debris to accumulate <br /> in the pool. Pool operator shall clean the bottom, sides,and other surfaces of the pool as often as necessary to keep pool surfaces clean <br /> and free of slime and algae. (CCR 65533) <br /> #22 Skimmer Assembly <br /> OBSERVATIONS:The skimmer weir door was off the hinges and in the basket. Install/replace weir. Corrected on site. <br /> The skimmer was missing an o-ring. Provide within 1 week. <br /> CALCODE DESCRIPTION:Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br /> maintained in accordance with manufacturer specifications. (CBC 31366) <br /> #30 Pool Equipment and Plumbing Maintained <br /> OBSERVATIONS:Observed leaking from pool pipe and under pool filter in pump room and leaking from pool water line <br /> pipe near outdoor shower. Repair leaks within 1 week. <br /> CALCODE DESCRIPTION:All equipment related to pool operations shall be installed and maintained in accordance with manufacturer's <br /> specifications and shall comply with applicable requirements established by applicable NSF/ANSI-50 performance standards. (CBC <br /> 31236) <br /> FA0018660 PR0360004 SC001 08/17/2022 <br /> EHD 36-01 Rev.09/16/2020 Page 2 of 3 Swimming Pool OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />