My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2022
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
5648
>
1600 - Food Program
>
PR0527393
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/30/2022 10:02:28 AM
Creation date
8/30/2022 9:57:38 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0527393
PE
3611
FACILITY_ID
FA0002168
FACILITY_NAME
ST MARYS HIGH SCHOOL
STREET_NUMBER
5648
Direction
N
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95207
APN
10209001
CURRENT_STATUS
01
SITE_LOCATION
5648 N EL DORADO ST
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br />Facility Name and Address: ST MARYS HIGH SCHOOL, 5648 N EL DORADO ST, STOCKTON 95207 <br />Swimming Pool Official Inspection Report <br /> #9 Ladders and Handrails <br />OBSERVATIONS: The middle ladder hand rail near the diving boards was loose. Secure hand rail today. <br />CALCODE DESCRIPTION: A means of entry and exit shall be provided at both the shallow and deep end of the pool. Ladders and <br />handrails shall be corrosion resistant and shall be rigidly installed. At least one handrail shall extend from the deck to not less than a point <br />above the top of the lowest step. Handrails shall be installed between 28 to 36 inches above the steps and deck. (CBC 3111B) Pool <br />operator shall keep ladders and handrails well maintained. (CCR 65535) <br /> #37 Electrical Hazards <br />OBSERVATIONS: GFCI was not located for pool lights during inspection. Locate and test GFCI for pool lights. Submit <br />evidence of correction to dafonskaia@sjgov.org within 2 weeks. <br />CALCODE DESCRIPTION: Electrical equipment installed in the water, walls, deck, or equipment room of a public pool shall comply with <br />California Electrical Code. (CEC 680.4) Light fixtures installed in the pool that operate at more than 15 volts shall be protected by a ground <br />fault circuit interrupter. (CBC 3160B) <br /> #38 Filter Cleaning and Maintenance <br />OBSERVATIONS: The influent and effluent pressure difference was greater than 10 PSI. Clean/backwash filter. <br />CALCODE DESCRIPTION: All filters shall be maintained in accordance with manufacturer's specifications. (CBC 3123B) Pressure gauge <br />located on the filter shall be marked with the clean startup reading. (CBC 3125B) Each filter vessel shall be provided with valves so that it <br />can be isolated from the recirculation system for repairs and backwashing. (CBC 3128B) <br />OVERALL INSPECTION NOTES AND COMMENTS <br />OBSERVATIONS <br />Flow rate:gpm <br />pH: <br />Chlorine:ppm <br />Cyanuric acid:ppm <br />Temp:º F 980 <br />7.4 <br />1.0 <br /><30 Combined chlorine:ppm <br />NOTES <br />Routine inspection. <br />Influent: 15 PSI <br />Effluent: 3 PSI <br />Main gate is only kept open when person with lifeguard certification is at pool, otherwise gate is kept locked. <br />The person in charge is responsible for ensuring that the above mentioned facility is in compliance with all applicable sections of the California Health and <br />Safety Code. If a reinspection is required, fees will be assessed at the current hourly rate. <br />Received by: Name and Title: <br />EH Specialist:Phone:(209) 616-3035 <br />, <br />DARIA AFONSKAIA <br />Page 2 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0002168 PR0527393 SC001 08/22/2022 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD
The URL can be used to link to this page
Your browser does not support the video tag.