My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2022
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1110
>
2300 - Underground Storage Tank Program
>
PR0547873
>
INSTALL_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/23/2023 11:37:08 AM
Creation date
9/6/2022 3:22:10 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2022
RECORD_ID
PR0547873
PE
2361
FACILITY_ID
FA0000794
FACILITY_NAME
7-ELEVEN INC # 41530
STREET_NUMBER
1110
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
21821023
CURRENT_STATUS
03
SITE_LOCATION
1110 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
197
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SUBMERSIBLE PUMPING SYSTEMS r <br /> ^ <br /> Franklin Fueling Systems I SUBMERSIBLE TURBINE PUMPS _ T <br /> Specifications -� <br /> • 11/2 Hp fixed speed models are available in variable Power Requirements + <br /> length and fixed length options. e 11/2 Hp fixed speed models require single-phase, <br /> • Check valve:2 3/4'diameter fluorocarbon seal 208-230 VAC, 60 Hz incoming power. <br /> constructed with cast aluminum body and steel <br /> backing washer. • 11/2 Hp fixed speed models incorporate a starting <br /> and running capacitor,with internal bleed resistor, <br /> • Pressure relief valve:available in four pressure relief rated 370 Volt, 15 microfarad. <br /> settings, integral to check valve.Standard model •STP-SCI single-phase smart controllers and STP-CBS <br /> relieves at 40 psi and resets above 35 psi. single-phase control boxes are available for 11/2 Hp <br /> •Syphon:venturi-type syphon primer supplied with pump control. <br /> every submersible.Syphon check valve and • Max. motor draw: 1 1 Amps. <br /> secondary syphon sold separately. <br /> •Air eliminator:every submersible includes a tank return Liquid Compatibility <br /> path with one-way check valve to provide active air •Max. liquid viscosity: 70 SSU at 60 OF (15 OC). <br /> elimination. <br /> • Electrical disconnect: electrical yoke for positive •Standard STP models are UL and cUL listed for fuel <br /> contractor disconnect during service. mixtures containing up to 10%ethanol with gasoline, <br /> and 20%MTBE,20%ETBE or 17%TAME with gasoline. <br /> Pump Motor •STPAG (AG compatible) models are UL and cUL listed <br /> • 11/2 Hp fixed speed,3450 rpm, multi-stage centrifugal for fuel mixtures containing diesel fuel with up to 20% <br /> type pump motor with integral,automatic,thermal biodiesel, 100%biodiesel, up to 85%ethanol with <br /> overload protection. gasoline,and 20%MTBE,20%ETBE or 17%TAME with <br /> gasoline. <br /> •Standard pressure (150,two-stage) model, max. <br /> pressure=34 psi. • 11/2 Hp fixed speed models can also be used with <br /> • High pressure (H150,three-stage) model, max. diesel fuels,fuel oils, kerosene,Avgas and jet fuels in a <br /> non-gelled pourable state. <br /> pressure=46 psi. •All wetted elastomers are made of a high grade, <br /> Approvals fluorocarbon compound. <br /> •cULus listed. Quality Certification <br /> •Consult factory for applicable approvals. • Franklin Fueling Systems is an ISO 9001 Certified <br /> Manufacturer. <br /> Performance <br /> 1 Y Hp Fixed Speed Turbine Performance Chart 11/2 Hp High Pressure Fixed Speed Turbine Performance Chart <br /> 110---------------- - 140 '-_ ----------- ---------------------- ---------------------- ----------- <br /> 130 --------- -- ------ --z------------------ --------------------- <br /> 120 ---------- ---- ----- ------- ------------ ---------------------- ----------- <br /> 90 ` <br /> ------- ----- - ------ ------- •cam--- ------- ------ Two STP150 Manifolded - <br /> ' 1'/Hp Pumps 110 ---------- ---- --- -- ---------------�-,---- - Two STPH150 Manifolded <br /> 11/2 Hp High Pressure Pumps <br /> w80 ------- ----- ---- -- ------- -----`- '•----- ---- --- 100 ---------- ----------- ---------------------- ------- <br /> 90 ---------- ----------- - -------------------- -- --------------- - ----------- <br /> , <br /> LL <br /> _ 80 <br /> a 60 - - ------- o <br /> ---------------- ----------- ------ - -------- <br /> x <br /> One STPH150 11/2 Hp 1• <br /> a 50 - One STP1501'/Hp PumP __ _________________ _______ __c,__ _ _____ _______ O 60 ___ High Pressure Pump __ _______________ ---------------,-____ _ ___________ <br /> o � <br /> 40 <br /> _______ _________ 50 ________________. - - ___________ <br /> ______ _______ _______ _______ _______ _______ _______ _______ <br /> __________ ___________ ________ _____________ _ <br /> 40 -------- <br /> -------- ------------ <br /> ------- ------- ------- ------- -- ---- ------- ------- ------- ----+-- --------- <br /> ---------- --------- -- <br /> 30 30 <br /> 20 ------ ------- ------- ---- -- ------- ------- ------- ------- ':------- 20 <br /> 10 ------ ------- ------- ------- - ------- ------- ------- ------- ---' <br /> 0 0 <br /> 0 20 40 60 80 100 120 140 160 180 200 0 20 40 60 80 100 120 140 <br /> Flow in Gallons per Minute fgpm) Flow in Gallons per Minute(gpm) <br /> Note:Performance based on pumping solvent(0.78 specific gravity).Pressure is taken at the manifold Note,Performance based on pumping solvent(0.78 specific gravity).Pressure is taken at the manifold <br /> discharge outlet <br /> STP150 models are powered by asingle-phase,60 Hz,208/230 Vol}power supply. discharge outlet.STPH 150 models are powered by a single-phase,60 Hz,208/230 Volt power <br /> supply. <br />
The URL can be used to link to this page
Your browser does not support the video tag.