My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2022
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1110
>
2300 - Underground Storage Tank Program
>
PR0547873
>
INSTALL_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/23/2023 11:37:08 AM
Creation date
9/6/2022 3:22:10 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2022
RECORD_ID
PR0547873
PE
2361
FACILITY_ID
FA0000794
FACILITY_NAME
7-ELEVEN INC # 41530
STREET_NUMBER
1110
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
21821023
CURRENT_STATUS
03
SITE_LOCATION
1110 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
197
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DECEIVED <br /> SA N J O A Q U I N Environmental Health Department <br /> COUNTY JAN 18 2022 <br /> ENVIRONMENTAL HEALTH <br /> DEPARTMENT <br /> F . SYSTEM PIPING CONTINUED : <br /> Check Code <br /> Box Section <br /> HSC Piping compatible with material intended to be stored . <br /> ❑✓ 25290 . 1 c 1 <br /> 25290 . 2 c 1 <br /> 23 CCR <br /> ✓ 2631 (b) Design and construction of piping approved by independent testing organization (e . g . UL) . <br /> ✓ Piping , including vent lines , sloped toward tank(s) with minimum 1 /8 inch slope per 1 foot of run . <br /> HSC <br /> 25290 . 1 kVapor recovery , fill riser, and vent line piping are secondarily contained . <br /> 25290 .2c3&u) <br /> G . OVERSPILL/ OVERFILL PREVENTION : <br /> Check Code <br /> Box Section <br /> 23 CCR Overspill containment having minimum capacity of 5 gallons provided at each tank fill location . <br /> ❑✓ 2635 (b) Manufacturer Fiberlite/OPW Model P7161 C- FLDV & P7161 C- FLPL <br /> Approved overfill prevention device provided at each tank fill location . <br /> Choose One of the following methods : <br /> ❑ Alert the transfer operator when the tank is 90 percent full by restricting the flow into the tank or <br /> triggering an audible visual alarm <br /> ❑ Restrict delivery of flow to the tank at least 30 minutes before the tank overfills , provided the <br /> 23 CCR restriction occurs when the tank is filled to no more than 95 percent capacity ; and activate an <br /> 2635(b) (2) audible alarm at least five minutes before the tank overfills <br /> Provide positive shut-off flow to the tank when the tank is filled to no more than 95 percent of <br /> capacity. <br /> ❑ Provide positive shut-off of flow to the tank so that none of the fittings located on the top of the <br /> tank are exposed to product due to overfilling . <br /> Manufacturer OPW Model 71 SO-410C <br /> H . CORROSION PROTECTION : <br /> Check Code <br /> Box Section <br /> X Fiberglass reinforced plastic ( FRP) <br /> Piping corrosion protection : ❑ Steel with cathodic protection or impressed current <br /> 23 CCR ❑ Steel isolated from contact with backfill <br /> 2636(b) <br /> X FRP or equivalent non-metallic exterior coatings or coverings <br /> Tank corrosion protection : ❑ Sacrificial Anode <br /> ❑ 23 CCR ❑ Steel tank with field installed cathodic protection or impressed <br /> 2635(a) (2) <br /> current <br /> ❑✓ Tie-downs , when used , constructed of non -corrosive material or coated steel . <br /> 7of8 <br />