My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2022
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1399
>
2300 - Underground Storage Tank Program
>
PR0231435
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/10/2023 3:00:21 PM
Creation date
9/22/2022 8:41:10 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0231435
PE
2361
FACILITY_ID
FA0000916
FACILITY_NAME
7-ELEVEN INC #19976
STREET_NUMBER
1399
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
21633034
CURRENT_STATUS
01
SITE_LOCATION
1399 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
60
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank <br />Monitoring System Certification Form <br />5. MONITORING SYSTEM AND PROGRAMMING <br />A separate Monitoring System Certification Form mast be prepared for each control panel. <br />Make of Monitoring System <br />Model of Monitoring System <br />Software Version Installed <br />Control Panel <br />Control Panel <br />Veeder Root <br />TLS -350 PLUS <br />334.00 <br />Attach the post -certification reports if the monitoring system is capable of generatng <br />yes <br />No <br />NA <br />either; AMonitoring System Set-up 0 Alarm History Report <br />All monitoring equipment is operational per manufacturer's specifications? <br />Secondary containment systems are free of damage, debris, or liquid? <br />R) <br />Are the audible and visual alarms operational? <br />0 <br />E) <br />All sensors have been. 1) visually inspected for wiring kinks, breaks and residual <br />buildup on floats; and 2) tested for functionality and confirmed operational? <br />Are all sensors installed to detect a release at the earliest opportunity in the <br />0 <br />Ll <br />El <br />secondary containment? <br />The monitoring system set-up was reviewed, and proper settings confirmed? <br />0 <br />E) <br />J <br />Was the monitoring control panel's backup battery visually inspected, functionally <br />A <br />Ll <br />Ll <br />tested, and confirmed operational? <br />Does the flow of fuel stop at the dispenser if a release is detected in the under- <br />0 <br />E) <br />L-1 <br />dispenser containment? <br />Does the turbine automatically shut down if the piping secondary containment <br />0 <br />D <br />Ll <br />monitoring system fails to operate or is electrically disconnected? <br />Does the turbine automatically shut down if the piping secondary containment <br />monitoring system detects a release? Which sensors initiate positive shut down? <br />0 <br />g <br />L-1 <br />(Chuck all that apply) Z Surnp 21 UDC <br />If monitoring system alarms are relayed to a remote monitoring center, is all <br />0 <br />E <br />L] <br />communication equipment operational? <br />Describe all answers marked "No`' or "Fail" and proposed remedy it Secdon 9. <br />List all monitoring equipment either replaced or repairer! in Section 9 <br />Page 2 of 6 <br />
The URL can be used to link to this page