My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SR0085076_OWTS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AHERN
>
29700
>
4200 – Liquid Waste Program
>
SR0085076_OWTS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/30/2022 4:13:58 PM
Creation date
9/29/2022 9:09:49 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4200 – Liquid Waste Program
FileName_PostFix
OWTS
RECORD_ID
SR0085076
PE
4201
FACILITY_NAME
AHERN TRUCK STOP
STREET_NUMBER
29700
Direction
S
STREET_NAME
AHERN
STREET_TYPE
RD
City
TRACY
Zip
95304
APN
25502014
ENTERED_DATE
3/29/2022 12:00:00 AM
SITE_LOCATION
29700 S AHERN RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\tsok
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
207
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
20 <br /> Paul W. Donoho, R.E.H.S. #6227 <br /> (530) 701-9972 <br /> AdvanTexO O&M <br /> COMMERCIAL TREATMENT SYSTEMS <br /> Inspection 'o (continued) <br /> Inspection Points-Vent Fan Assembly 3.Leak inspection:Ono <br /> A Current sensor monitors <br /> the distribution valve is <br /> pressurized,inspect the <br /> the vent fan operation.It unions on the distribution <br /> the fan fails,this sensor valve for leaks.Tighten any } <br /> will open and activate unions that are leaking. <br /> an alarm.Some vent fan <br /> assemblies are equipped 4.Operation inspection: <br /> with optional heater units Open and close the ball valve <br /> for reliable performance in to test the operation of the <br /> cold weather, Checkyour distribution valve. <br /> system plans to determine it your vent fan assembly includes a heater. • When the valve is closed and opened,the flow should transition <br /> 1.Current sensor operation:To test the current sensor,switch off from one leg of the valve to anollner.Observe the clear section of <br /> the leg to verify this transition.There may be flow in more than <br /> the power to the fan and verify the visual alarm on the control panel one leg,but there should only be full flow in one leg at anytime. <br /> is activated. • When the ball valve is fully closed,the system will fully pressurize <br /> NOTE:TCOMcontrol panels have a 12-hourdelayin the audible (deadhead condition).Incorrectly installed connections in the line <br /> alarm for the current sensor may separate and require reinstallation before testing can be <br /> completed. <br /> 2.Optional heater unit:There are two types of heater unit controls • If the distribution valve does not rotate correctly,open the <br /> available for vent fan assemblies:a single set-point style and a distribution valve and inspect for debris or breakage.It the <br /> multiple set-point style.If your system is equipped with an optional problem is not a mechanical issue,review the plans for potential <br /> heater unit,check your system plans to determine the type of heater installation issues,including elevation. <br /> included in the vent fan assembly. Housekeeping <br /> • Single set point—bate the heater inside the vent fan assembly <br /> enclosure,remove the heater cover in the vent fan assembly,and 1 Verify that all control panels are turned on and all"AUTO-OFF-MAN" <br /> set the thermostat to 43°F(6°C). switches are toggled to"AUTO." <br /> • Multiple set points—In the control panel,set the"Heater On" 2.Close all control panels. <br /> point at 35°F(1.6°L7,"Heater Off"point to 45°F(7.2°C),"Fan <br /> On"point to 35°F(1.6°C),and"Fan Off"point to 25°F(-3A°C). 3.Close and bolt down all tank access lids and riser lids. <br /> Inspection Points—Distribution Valve WARNING:ANUN80LTED RlSERLIDOROPEN TANKISA <br /> SAFETMAZARD?Tank and riser access lids must be properly <br /> To verify that the distribution valve is operational,the valve must be secured at all times.if bolts are lost or damaged contactOrenco <br /> hydraulically loaded with the conditions under which it will operate.Use the immediately forreplacements. <br /> system plans to find the location of all distribution valves in the system. <br /> 4.Police the area for <br /> 1.Verily liquid level:Make sure that the tank or basin[hat you are debris and tools. e <br /> pumping from has sufficient liquid to perform the test. ' <br /> WARNING:There is no motor protection in TCOM panels and <br /> panels without"RO-alarms.Before running a pump,always <br /> verify that there is sufficient liquid in the tank or basin. <br /> 2.Tum on pump:Toggle the"AUTO-OFF-MAN"switch for the pump <br /> that pressurizes the distribution valve to"MAN." <br /> AIM-OM-ATX-3,nEv.�2.1,0.5115 •••Copyright Orenco Sys#ems®,Inc�Pmperly of Orenco Systems°°,IVc o nal reproduce or di; ule wlinout wrL;authorizHtion from Orenw'80044i W437 <br />
The URL can be used to link to this page
Your browser does not support the video tag.