My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SR0085076_OWTS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AHERN
>
29700
>
4200 – Liquid Waste Program
>
SR0085076_OWTS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/30/2022 4:13:58 PM
Creation date
9/29/2022 9:09:49 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4200 – Liquid Waste Program
FileName_PostFix
OWTS
RECORD_ID
SR0085076
PE
4201
FACILITY_NAME
AHERN TRUCK STOP
STREET_NUMBER
29700
Direction
S
STREET_NAME
AHERN
STREET_TYPE
RD
City
TRACY
Zip
95304
APN
25502014
ENTERED_DATE
3/29/2022 12:00:00 AM
SITE_LOCATION
29700 S AHERN RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\tsok
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
207
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Design Criteri rencor <br /> Using Equation B3 from Appendix B provides the alkalinity demand for this project: <br /> 5 mg/L alkalinity <br /> Alkalinity Demand = 160 mg/L TKN x = 800 mg/L <br /> 1 mg/L TKN <br /> Using Equation B4 from Appendix B provides the alkalinity need for the project: <br /> Alkalinity Need = 800 mg/L + 100 mg/L— 120 mg/L = 780 mg/L <br /> These equations show that alkalinity addition is required for this system. <br /> Design Specifics <br /> Tankage Requirements <br /> Depending on the size of the facility,distributed tankage or a small gravity collection system to primary tankage is typically used.For systems with <br /> gravity collection,especially in areas with significant rainfall,an adjustment to the per capita flow may be necessary. <br /> Schools fall within Application Type 3 in Appendix A;therefore total primary tank recommendations call for a minimum of 3 days' retention at <br /> maximum day design flow.Since a pre-anoxic tank will be used due to the nitrogen reduction requirement,two days of primary tankage will be <br /> recommended with an additional one-day pre-anoxic tank situated at the treatment site. <br /> Table 3A-3:Sample Tank Sizing Recommendations(With Flow Equalization) <br /> Source Equalized Design Daily Flow(gpd) Recommended Minimum Tank Size(gallons) <br /> Grease Tankage 2,100' 6,300 <br /> Primary Tankage 10,500 21,000 <br /> EQ Tank 10,500 10,500 <br /> Pre-Anoxic Tank 10,500 10,500 <br /> 1 st Stage Recirculation Tank' 10,500 7,875 <br /> Post-Anoxic Tank 10,500 5,250 <br /> 2nd Stage Recirculation Tank3,4 10,500 2,625 <br /> Discharge Tank 10,500 2,100 <br /> 'Grease flow estimated at 20%of Design Flow <br /> 2 Only for AX100 Systems;volume included in AX-Max Systems <br /> 3 Sized at 25%of Design Flow(see page 17) <br /> °Only for AX100 Systems;volume included in AX-Max Systems <br /> Since the system is required to treat for organic constituents and provide nutrient reduction,it would be configured as shown in Figure 3A-1. <br /> Alkalinity Feed Carbon Feed <br /> Pre-Anoxic Return Line <br /> Primary EQ Pre- 1st Stage Post- 2nd Stage Discharge <br /> Treatment Tank Anoxic AdvanTex Anoxic AdvanTex <br /> Figure 3A-1.Treatment Configuration for Organic Constituents <br /> When using Flow Equalization,all calculations are performed with the Equalized flow considered as the Design Average Day Flow.Calculations for <br /> Maximum Day Design Flow are unnecessary. <br /> Orenco Systems°•800-348-9843•+1 541-459-4449•www.orenco.com NDA-ATX-1 <br /> Rev.8,©10/20 <br /> Page 35 of 38 <br />
The URL can be used to link to this page
Your browser does not support the video tag.