Laserfiche WebLink
From: WESLEY DONOHO <br /> To: Wona.Jeff rEHDI <br /> Subject: Re: 29700 Ahern Engineered OWTS for Apna Petroleum SR0085076(PA-1600049) <br /> Date: Wednesday,June 1,2022 11:33:00 AM <br /> Attachments: 200924-Revised Daily Use(2).docx <br /> NCS-6.pdf <br /> NDA-ATX-1.)d <br /> CAUTION:This email is originated from outside of the organization. Do not click links or open attachments unless <br /> you recognize the sender and know the content is safe. <br /> Jeff: <br /> I have attached the document I was given for the loading on this system. I was told this had been <br /> approved so I didn't question it. I also checked on the usage of a truck stop in Bakerfield that had a <br /> system designed for a similar load and they told me their average daily use was about 3,500 gallons and <br /> they have Washers and Showers in their facility. <br /> I have also attached the design manual from Orenco that I used to design the system from. It is where all <br /> of the figures for my calculations came from. It is a pretty comprehensive document and covers many <br /> scenarios. I designed the system to reduce the Nitrates to a point that with ground treatment in the <br /> trenches I felt the effective Nitrate load would not be greater than 10 mg/L. I have resubmitted the <br /> information to Orenco to see what their calculations will show. I will forward their response to you once I <br /> receive it. <br /> I have also attached a case study of a system using the AX-100 pod to achieve discharge limits. If you <br /> have any more questions or comments, please let me know. <br /> Thank you and have a great day, <br /> Paul Donoho <br /> On Wednesday, May 25, 2022, 04:54:30 PM PDT, Wong,Jeff[EHD] <jwong@sjgov.org>wrote: <br /> Paul: <br /> Per our phone conversation, please provide additional information for the 2/28/2022 engineered OWTS <br /> stamped by Ross Shoaf(the Plan): <br /> 1) The numbers used to calculate the estimated maximum daily load, 6,450 gallons/day(and average of <br /> 3,225 gpd) , is different from the 7,095 gpd (derived from 845 gpd (employee) + 6,250 gpd (facility)) used <br /> in the Nitrate Loading Calculation in the NLS/SSS dated 3/4/2020 (Project No.1947) prepared by Live <br /> Oak Geo Environmental, Inc. The EHD 1/7/2021 Condition of Approval letter for the Use Permit <br /> application PA-1600049, Item#4, requires the OWTS be based on the findings of the NLS/SSS. Please <br /> provide information/sources in support of the different parameters being used to design the OWTS. <br /> 2) Many numbers used in the calculations on Page 5 of the Plan haves no legend or explaination. <br />