Laserfiche WebLink
PART C-AIR MONITORING, WORKER EXPOSURE MONITORING <br /> C.I. AIR MONITORING(Direct-Reading Instruments) ® Applicable ❑ Not Applicable,Not Anticipated <br /> EXPLANATORY NOTES,CLARIFICATIONS: <br /> Volatile Organic Compounds:Air monitoring of worker breathing zone will be performed by Geosyntec personnel while(i)borings are being advanced,(ii)new monitoring <br /> wells are being installed into auger casings,(iii)when grouting to surface,and(iv)when developing new monitoring wells. A photoionization detector with 11.7 eV lamp, <br /> properly calibrated in accordance with manufacturer's instructions,will be used for monitoring of volatile organic compounds(VOCs)in the worker breathing zone during <br /> these activities. Worker breathing zone readings will be recorded on no less than a 15-minute frequency. Background readings will also be recorded and any sustained <br /> (longer than 5 seconds)detection above background levels will result in work stoppage so that engineering controls can be instituted;this will consist of electrically <br /> powered fans for the displacement of VOCs from the breathing zone. If sustained(longer than 5 seconds)detections above background level are still detected after <br /> engineering controls are in place then work shall stop and either additional engineering controls shall be put in use before resuming work activities or the boring will be <br /> terminated. <br /> The primary VOC compound of concern is Propylene dichloride which has a ACGIH®2018 8 hour limit of 10 ppm. <br /> ® s'AIR-TESTING ®VOCs,GASES ❑Flammable gas(LEL) <br /> PARAMETERS ®PID, Lamp energy: 11.7 eV j❑Particulate(dust) <br /> ❑FID ❑Calibration kit for each parameter <br /> ❑Carbon monoxide ❑Other: <br /> ❑Hydrogen sulfide <br /> ❑Oxygen(02) <br /> ACTION LEVELS FOR El E]Oxygen <19.5%-ventilate to raise 02 to acceptable levels,or use Level B. <br /> 02/LEL >23.0%-ventilate to lower 02 to acceptable levels,or use Level B and control fire hazards&ignition sources. <br /> . .. .. . . ...... ................... ............ <br /> ❑LEL Confirm at least 12%oxygen is present to ensure accuracy of LEL readings. <br /> At<10% LEL-Continue working,continue to monitor LEL levels <br /> At>10% LEL-Immediately withdraw from area. Resume work ONLY after LEL readings reduced to<10%. <br /> ® ACTION LEVELS FOR Parameters Level D,Modified D* Use levels C or B*,as indicated below,OR take action to reduce breathing <br /> TOXICS zone level to concentration acceptable for Level D*. <br /> ...................... .. .......... <br /> (sustained ®VOCs < 2 ppm <br /> i breathing zone > 2 ppm:Ventilate area with fans,leave and return once levels have <br /> concentrations) ................................................................................................................................................................................................................................................................................(..................pplied respirator) <br /> decreased or don Level B air-su <br /> ❑Carbon Monoxide <35 ppm >35 ppm- Level B (air-supplied respirator) <br /> ........................................................................................................................................................................... _......__...----...-............................... <br /> ❑Hydrogen Sulfide <10 ppm >10 ppm-Level B (air-supplied respirator) <br /> .......................................................................-............................................._.............................................................................................................................................._......._._.........._..___•-----._.._.................... <br /> ❑Total Dust < _ mg/m3 >_ mg/m3-Level C (air-purifying respirator) <br /> ...................................................................................................................-................................................................................................................................................................................................_._....__............ <br /> ........... <br /> El <br /> ..............................................................................................................................................................._.........._...._.,._......................................................................................................................................................................................................................................._._._._........................ <br /> *Levels of Protection: Level D(standard work clothes,basic personal protective wear,no chemical protective clothing,no respiratory protection) <br /> Modified Level D(chemical protective clothing in addition to standard work clothes,no respiratory protection) <br /> Level C(air purifying respirator or dust mask,in addition to chemical protective clothing) <br /> Level B or A(air supplied respirator,chemical protective suit;fully-encapsulating suit for Level A,special application chemical protective <br /> gloves) <br /> Geosyntec Procedures: HS-111-Air Monitoring <br /> C.2. OTHER WORKER EXPOSURE MONITORING ❑ Applicable ® Not Applicable,Not Anticipated <br /> ❑Air Sampling(sample collection,passive dosimeter) ❑Ionizing or Non-ionizing Radiation Testing i ❑ Heat Stress Testing <br /> ❑Wipe/Bulk Sampling(to evaluate worker exposure) ❑Noise Testing <br /> El Other <br /> EXPLANATORY NOTES,CLARIFICATIONS: <br /> Geosyntec Procedures: HS-109-Hearing Protection,HS-111-Air Monitoring,HS-124-Heat Stress Prevention,HS-126-Radiation Safety Program, <br /> HS-128-Ionizing and Non-ionizing Radiation, HS-601-Asbestos,HS-602-Lead <br /> Geosyntec° THA—Drilling/Development Operations Safety 1/29/2019 <br /> GSH Stockton Phyto,TR0712C Page 13 <br /> consultants <br />