Laserfiche WebLink
M4?,- <br />SYSTEM CONSTRUCTION <br />1. THE SEPTIC SYSTEM COMPONENTS AND INSTALLATION SHOULD BE ACCORDING TO SAN JOAQUIN <br />COUNTY ENVIRONMENTAL HEALTH SEWAGE STANDARDS. <br />2. THE SIDES AND BOTTOM OF ALL LEACH LINE TRENCHES AND THE SIDES OF THE DRY WELLS SHOULD BE <br />RAKED OR SCARIFIED PRIOR TO THE PLACEMENT OF GRAVEL TO ELIMINATE AN SOIL "SMEARING" THAT <br />MAY HAVE OCCURRED DURING EXCAVATION. SINCE THIS IS CRITICAL, ALL TRENCH AND DRY WELL <br />EXCAVATIONS SHOULD BE INSPECTED BY A REPRESENTATIVE OF NEIL O. ANDERSON a ASSOC. PRIOR TO <br />THE PLACEMENT OF ANY GRAVEL. <br />3. FINAL GRADING OF THE SURFACE OF THE DISPOSAL FIELDS SHOULD BE SUCH THAT DRAINAGE WATER IS <br />NOT ALLOWED TO COLLECT OR POND OVER THE FIELDS. <br />4. NO PERMANENT STRUCTURES OR HARD SURFACES (I.E. CONCRETE FLATWORK, ASPHALT PAVING, ETC) <br />SHOULD BE CONSTRUCTED OVER THE LEACH FIELDS. <br />S. THE ONLY LANDSCAPING PERMITTED OVER THE INSTALLED LEACH FIELDS IS GRASS OR LOW SHRUBS. A <br />MINIMUM SEPARATION OF 10 FEET SHOULD BE MAINTAINED BETWEEN THE LEACH FIELDS AND PLANTED <br />TREES OR DEEP ROOTED SHRUBS. <br />6. THE DESIGNATED REPLACEMENT AREA SHOULD BE KEPT FREE OF ANY PERMANENT STRUCTURES (I.E. <br />SWIMMING POOLS]. <br />SYSTEM MAINTENANCE <br />THE INSTALLED SYSTEM WILL CONSIST OF DUAL DISPOSAL FIELDS. TO OBTAIN THE OPTIMUM <br />PERFORMANCE AND MAXIMUM LIFE OF THE SYSTEM, MANUAL SWITCHING OF THE DISPOSAL FIELDS <br />SHOULD BE PERFORMED ON AN ANNUAL BASIS. THE SYSTEM INCLUDES TWO PUSH-PULL VALVES, ONE <br />ON EACH OF TWO EXITING EFFLUENT LINES FROM THE SEPTIC TANK, LOCATED IN THE SECOND SEPTIC <br />TANK MANHOLE. ON AN ANNUAL BASIS, THE MANHOLE COVER SHOULD BE REMOVED AND THE ONE <br />VALVE RISER "PUSHED" DOWN OR CLOSED AND THE OTHER VALVE RISER "PULLED" OR OPENED. THIS <br />WILL SWITCH THE EXITING SEPTIC TANK EFFLUENT FLOW FROM ONE LEACH FIELD TO THE OTHER. <br />2. THE SEPTIC TANK IS REQUIRED TO BE PUMPED AND CLEANED A MINIMUM OF EVERY THREE (3) YEARS. <br />ACCESS TO THE SEPTIC SYSTEM DISPOSAL FIELD BY SERVICE EQUIPMENT SHOULD BE MAINTAINED. <br />3. A SEPTIC SYSTEM OPERATES BY UTILIZING MICRO ORGANISMS TO CONSUME WASTE PRODUCTS. <br />HOUSEHOLD CHEMICALS, PAINTS, OR MINERAL SALT FROM A WATER SOFTENER SHOULD BE KEPT OUT <br />OF THE SEWER/SEPTIC SYSTEM AS THESE SUBSTANCES ARE HARMFUL TO THE NECESSARY ORGANISMS. <br />4. POSITIVE DRAINAGE AWAY FROM THE DISPOSAL FIELDS SHOULD BE MAINTAINED AT ALL TIMES. <br />AS HOMEOWNER, I HAVE READ AND UNDERSTAND THE ABOVE CONSTRUCTION AND MAINTENANCE NOTES <br />AND AGREE TO PERFORM THE ABOVE RECOMMENDED SYSTEM MAINTENANCE. I ALSO AGREE TO TRANSFER <br />THESE PLANS AND THE INFORMATION CONTAINED HEREON TO THE NEW OWNER UPON SALE OF THE TITLED <br />RESIWNCE. % <br />DA <br />l I YcG4� )O it <br />PRINTED NAME <br />