Laserfiche WebLink
FGL Environmental Doc ID:3DO900002_SOP_12.DOC <br /> Revision Date: 10/09/14 Page 1 of 1 <br /> Inte tory Condition Upon Receipt (Attach to COC) fj�wo6z(az <br /> Sample Receipt : STK CC CH VI <br /> 1. Number o e ch ages received: Shipping tracking# <br /> 2. Were samples received in a chilled condition? Temps: <br /> Surface water SWTR bact samples: A sample that has a temperature upon receipt of >10°C,whether iced or not, <br /> should be flagged unless the time since sample collection has been less than two hours. <br /> 3. Do the number of bottles received agree with the COC? No N/A <br /> 4. Were samples received intact? (i.e. no broken bottles, leaks e o <br /> 5. VOAs checked for Headspace? Yes N <br /> 6. Were sample custody seals intact? Yes N <br /> 7. If required, was sample split for pH analysis? N <br /> 8. Were all analyses within holding times at time of receipt? No <br /> 9. Verify sample date,time and sampler name es o <br /> Sign and date the COC,place in a ziplock and put in e e ice chest as t e samples. <br /> Sample Receipt Review completed by (initials): <br /> Sample Receipt at SP: <br /> 1. Were samples received in a chilled condition? Temps: <br /> Acceptable is above freezing to 6`m C. If many packages are received at one time check for tests/H.T.'s/rushes/ <br /> 2. Shipping tracking numbers: <br /> 3. Do the number of bottles received agree with the COC? Yes No N/A <br /> 4. Were samples received intact? (i.e. no broken bottles, leaks etc.) Yes No <br /> 5. Were sample custody seals intact? Yes No N/A <br /> Sign and date the COC,obtain LIMS sample numbers, select methods/tests and print labels. <br /> Sample Verification, Labeling and Distribution: <br /> 1. Were all requested analyses understood and acceptable? Yes No <br /> 2. Did bottle labels correspond with the client's ID's? Yes No <br /> 3. Were all bottles requiring sample preservation properly preserved? Yes No N/A FGL <br /> lException:Oil&Grease,VOA and CM verified in labs <br /> 4. VOAs checked for Headspace? Yes No N/A <br /> 5. Have rush or project due dates been checked and accepted? Yes No N/A <br /> 6. Were all analyses within holding times at time of receipt? Yes No <br /> Attach labels to the containers and include a copy of the COC for lab delivery. <br /> Sample Receipt, Login and Verification completed by (initials): <br /> Discrepancy Documentation: <br /> Any items above which are "No" or do not meet specifications (i.e. temps)must be resolved. <br /> 1. Person Contacted: Phone Number: <br /> Initiated By: Date: <br /> Problem: <br /> Resolution: <br /> (3017919) <br /> 2. Person Contacted: San Joaquin County EHD <br /> Initiated By: <br /> Problem: STE252062 <br /> Resolution: <br /> iv 08125/2022 07:53:02 <br /> (Please use the back of this sheet for additional comm IN 11111 <br /> contacts) STK2252062 <br />