Laserfiche WebLink
SAN J O A Q U I Environmental Health Department <br /> Food Program Official Inspection Report <br /> Facility Name and Address: MANTECA DONUT, 1194 N MAIN ST, MANTECA 95336 <br /> #34 Warewashing Facilites Maintained <br /> OBSERVATIONS:Provide proper chlorine test strips to check the chlorine 100 ppm concentration in the sanitizer bucket <br /> and the sanitizing compartment of the 3 comp sink. Correct in 1 week. Repeated violation. <br /> CALCODE DESCRIPTION:Food facilities that prepare food shall be equipped with warewashing facilities. Testing equipment and <br /> materials shall be provided to measure the applicable sanitization method. (I14067(f,g), 114099, 114099.3, 114099.5, 114101(a), <br /> 114101.1, 114101.2, 114103, 114107, 114125) <br /> #41 Plumbing Maintained;Approved Back Flow Device <br /> OBSERVATIONS:3 comp sink right side water faucet unit is lacking goose neck faucet and hot water knob. Right side <br /> faucet unit is not functional. Repair/replace right side water faucet unit in 2 weeks. Repeated violation. <br /> CALCODE DESCRIPTION:The potable water supply shall be protected with a backflow or back siphonage protection device,as required <br /> by applicable plumbing codes. (114192)All plumbing and plumbing fixtures shall be installed in compliance with local plumbing <br /> ordinances, shall be maintained so as to prevent any contamination,and shall be kept clean,fully operative,and in good repair. Any hose <br /> used for conveying potable water shall be of approved materials,labeled,properly stored,and used for no other purpose. (114171, <br /> 114189.1, 114190, 114193, 114193.1, 114199, 114201, 114269) <br /> #43 Toilet Facilites Clean/Supplied/Maintained <br /> OBSERVATIONS:Rest room hand sink is lacking paper towels. Provide paper towels today. Repeated violation. <br /> Rest room door is kept open during my inspection. Provide self closing door in 2 weeks. Repeated violation. <br /> CALCODE DESCRIPTION:Toilet facilities shall be maintained clean, sanitary and in good repair. Toilet rooms shall be separated by a <br /> well-fitting self-closing door. Toilet tissue shall be provided in a permanently installed dispenser at each toilet. The number of toilet <br /> facilities shall be in accordance with local building and plumbing ordinances. Toilet facilities shall be provided for patrons:in <br /> establishments with more than 20,000 sq ft. establishments offering on-site liquor consumption. (114250, 114250.1, 114276) <br /> #45 Floors,Walls, Ceilings; Clean and Maintained <br /> OBSERVATIONS:Floor and hard to reach corners, under the storage shelves, under the dry food containers, under and <br /> around the dough mixer and under the fryer station, have food debris and grease. Detail clean these areas today. Repeated <br /> violation. <br /> Base, under the 3 comp sink and grease trap, has missing coved base tiles. Repair base at this area in 2 weeks. <br /> The walls, across and on the right side of the 3 comp sink, are lacking coved base tiles. Provide coved base tiles in 2 <br /> weeks. <br /> RUBBER AND VINYL SHEETS ARE NOT PERMITTED IN THE WASHING AREA. <br /> CALCODE DESCRIPTION: The walls/ceilings shall have durable,smooth,nonabsorbent,light-colored,and washable surfaces. All floor <br /> surfaces, other than the customer service areas, shall be approved, smooth, durable and made of nonabsorbent material that is easily <br /> cleanable.Approved base coving shall be provided in all areas,except customer service areas and where food is stored in original <br /> unopened containers. Food facilities shall be fully enclosed. All food facilities shall be kept clean and in good repair. (114143(d), <br /> 114266, 114268, 114268.1, 114271, 114272) <br /> FA0000847 PRO162243 SCO01 10/31/2022 <br /> EHD 16-23 Rev.09/16/2020 Page 2 of 3 Food Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />