My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SR0085267
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
ARBOR
>
9409
>
4200 – Liquid Waste Program
>
SR0085267
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/6/2022 11:04:33 AM
Creation date
10/6/2022 10:27:49 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4200 – Liquid Waste Program
RECORD_ID
SR0085267
PE
2602
STREET_NUMBER
9409
Direction
W
STREET_NAME
ARBOR
STREET_TYPE
AVE
City
TRACY
Zip
95304
APN
21216020
ENTERED_DATE
5/12/2022 12:00:00 AM
SITE_LOCATION
9409 W ARBOR AVE
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\tsok
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
210
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LEGEND ■ <br /> PROPOSED MANHOLE AND COVER PER DETAILS 5 AND 6 ON SHEET <br /> 8 \ • C7.1 <br /> C7.2 ■ ■ ■ \ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ® PROPOSED DRAIN INLET PER DETAIL 16 ON SHEET C7.0 <br /> \ tt t G ® PROPOSED SANITARY SEWER CLEANOUT PER DETAIL 18 ON SHEET <br /> C7.0 <br /> 15 SDDI 3I � H GATE VALVE PER DETAIL 9 ON SHEET C7.1 <br /> - - - - - - - - - - - - - - - - <br /> NV 13 36 6"S - - - - - - - 4"SS - - - - - - ® POST INDICATOR VALVE PER DETAIL 10 ON SHEET C7.1 S I E G F R I E D <br /> ' \ <br /> S=0.0016 @ 70LF PERF � � � - - - - - - - 4"SS S=0.0016 @ 70LF PERF PROPOSED FIRE DEPARTMENT CONNECTION PER DETAIL 3 ON SHEET <br /> INV 1 . C7.1 3428 Brookside Road NV 16.084"W 4"SS - - - - - - - i - - - - - - - 4"SS - - Stockton,California 95219 <br /> 2"SSFM S=0.0016 @ 70LF PERF S=0.0016 @ 70LF PERF PROPOSED FIRE HYDRANT PER DETAIL 1 ON SHEET C7.1 209-943-2021 <br /> 14LF @ S=0.0000 I \ I SSDB 2 Fax: 209-942-0214 <br /> 32LF @ S=0.0000 4"SS - - - - I I 4"SS - - INV 16.58 4"E SS PROPOSED SANITARY SEWER LINE www.siegfriedeng.com <br /> 4"SSFM S=0.0016 @ 70LF PERF _.0 <br /> �� I S-0.0016 @ 70LF PERF <br /> 1 JJ� - - - 4"SS - - - - - - - �4'SM2"SSFM SS PROPOSED PERFORATED PIPE <br /> S=0.0016 @ 70LF PERF I \ � � 4"SSjV�6 LF0000 47LF @ S=0.0000 PERF <br /> \ I S=0.0016 @ 70LF PERF SSFM PROPOSED SANITARY SEWER FORCE MAIN <br /> - - - - - - - - - - <br /> 4"SS � <br /> SD PROPOSED STORM DRAIN LINE <br /> S=0.0016 @ 70LF PERF � \ � � 4"SS Q�OF ESS/0 <br /> - - - - - - - - - - - - - - - - - - S=0.0016@70LFPERF �� SC <br /> - - - - - - - - - - - - - - - - - PROPOSED WATER LINE <br /> FS PROPOSED FIRE SERVICE LINE <br /> 00 <br /> LO <br /> p9p o \ FH PROPOSED FIRE HYDRANT LINE <br /> P. 09/3 /23 <br /> CD 9 LEI: <br /> KEY NOTES UF CAO� <br /> J <br /> SDAD 1 DATE SIGNED: 09/13/22 <br /> 26 RIM 15.72 O FIRE HYDRANT PER DETAIL 1 ON SHEET C7.1 <br /> INV 12.67 6"S <br /> O4"WATER METER AND BACKFLOW PREVENTER PER C.O.T. <br /> SDMH 4 7 SDMH 3 SDDI 1 16 STANDARD PLAN 404&406 <br /> SDMH 5 7 RIM 16.73 RIM 16.26 O SEE FIRE SPRINKLER PLANS FOR CONTINUATION <br /> RIM 16.85 7 RIM 16.73 <br /> .92 INV 12.6618"W INV 12.44 24"W <br /> INV 13.07 12"SW INV 12.92 15"W M o <br /> INV 13.07 15"E INV 12.92 18"E INV 12.66 24 E O Y INV 12.44 24"E 40 SEE PLUMBING PLANS FOR CONTINUATION <br /> INV 12.92 12"S INV 12.66 12"S N o EO INV 12.44 12"SE <br /> INV 13.07 6"N 49LF S=0.0015 N C 99LF @ S=0.0015 222LF @ S=0.0015 <br /> @ � - 0 10"DOUBLE CHECK DETECTOR BACKFLOW PREVENTION <br /> 15"SD 18"SD <br /> -."SD 24"SD 24"SD 5 ASSEMBLY PER DETAIL 18 ON SHEET C7.0 <br /> SDDI 4 15 97LF @ S=0.0015 174LF @ S=0.0015 SANITARY SEWER PUMP STATION WITH FLOW METER <br /> RIM 16.22 <br /> INV 13.28 12"S 7 SDMH 2 O PER DETAIL 2 ON SHEET C7.2.SEE DETAIL FOR PUMP SIZING <br /> INV 13.28 12"NE .,p� RIM 16.72 6��F 18'S� INFORMATION <br /> 5 INV 12.59 24"W @ S, <br /> INV 12.59 24"E O00 24 O STORM DRAIN MANHOLE AND COVER PER DETAIL 5&6 ON <br /> 10 INV 12.59 18"E SD <br /> 6 SHEET C7.1 <br /> 10 10 INV 12.59 6"N 16 RIM 16.16 24 O SANITARY SEWER CLEANOUT PER DETAIL 17 ON SHEET C7.0 <br /> INV 12.68 18"SE18 <br /> 10TH 10"FHINV S� 10"FH <br /> 0 10"FS SDAD 2 10 Op?� 15 SDDI 2 O GATE VALVE AND VALVE BOX PER DETAIL 9 ON SHEET C7.1 <br /> 0 <br /> N ® 0 26 RIM 13.29 RIM 15.48 <br /> CD <br /> INV 12.65 12"NW <br /> ® ® CD o INV 12.75 6"SW 10 THRUST BLOCK PER DETAIL 4 ON SHEET C7.1 <br /> O Cn� n <br /> Ua 9 1 @) � ® SDWYE 1 60L�@ \ 11 FIRE DEPARTMENT CONNECTION PER DETAIL 3 ON SHEET C7.1 <br /> INV 12.70 18"S <br /> M <br /> co S=0.0050 12 2" IRRIGATION METER AND BACKFLOW PREVENTER PER <br /> INV 12.70 18"NW <br /> INV 12.70 6"NE DETAIL 7 ON SHEET C7.1 <br /> 13 IRRIGATION POINT OF CONNECTION. SEE LANDSCAPE PLANS <br /> FOR CONTINUATION <br /> 14 CONNECT TO EXISTING 12"FIRE HYDRANT LOOP <br /> 15 12"X12"DRAIN INLET PER DETAIL 15 ON SHEET C7.0 <br /> SDTD 1 SDTD 1 1j8 <br /> = RIM 15.83 RIM 15.83 ZA, 16 24"X24"DRAIN INLET PER DETAIL 15 ON SHEET C7.0 <br /> INV 13.07 12"N INV 12.8112"N <br /> SO 0075 17 TRENCH DRAIN PER DETAIL 16 ON SHEET C7.0 <br /> ° CONTRACTOR TO VERIFY EXISTING INVERT AND NOTIFY <br /> PHELAN <br /> 3 4 3 4 18 ENGINEER IMMEDIATELY OF ANY CONFLICTS D EVELOPM ENT <br /> 19 CONNECT TO EXISTING STORM DRAIN INLET 450 Newport Center Drive, Suite 230 <br /> 10 Newport Beach, CA 92660 <br /> N 20 ADJUST TO GRADE <br /> 141)U <br /> 21 5000 GALLON SEPTIC TANK PER DETAIL 1 ON SHEET C7.2 <br /> LU <br /> L22 2"BACKFLOW PREVENTER PER DETAIL 7 ON SHEET C7.1 BUILDINGS H& <br /> LU <br /> A- LU23 4X4X4 TEE WITH 2-1/2"REDUCERS ON NORTH AND EAST LEGS HOLLY COMMERCE CENTER <br /> 0) 24 WATER CROSSING PER DETAIL 11 ON SHEET C7.1 <br /> 1 910 7 SDMH 6 Z 6"SS LATERAL TO FIRE PUMP ROOM FLOOR DRAIN.TEST FLOW <br /> RIM 17.67 21tF 12"SQ O 25 SHALL BE LIMITED TO 100 GALLONS TWICE A YEAR DO TO SEPTIC <br /> INV 12.9715"S @ S;p�� H TANK AND LEACH FILED LIMITATIONS. <br /> EXISTING 0 0 0 0 0 0 0 0 INV 12.97 18"NW SDDI 11 Q 9375 SUGAR RD <br /> PROPERTY INV 12.97 12"E RIM 17.56 26 AREA DRAIN PER DETAIL 10 ON SHEET C7.1 TRACY, CA 95304 <br /> U) INV 13.13 12" Z_ - <br /> LINE � � ���� - � _ _�-�- �i �.� �� Ao <br /> ~ 27 CURB-O-LET PER DETAIL 13 ON SHEET C7.1 !. <br /> O <br /> O O <br /> co <br /> CD CDCD <br /> SSWYE 6 MILESTONES: <br /> o C) 0 5 INV 16.32 6"W <br /> (n � II INV 16.32 6"s 0 UTILITY CONSTRUCTION NOTES 28 JANUARY 2022 <br /> � LI_ <br /> � � INV 16.32 6"E BUILDING DEPARTMENT SUBMITTAL <br /> J CV U_ 1 <br /> `O <br /> Q0 v 29LF @ SSCO 6 8 <br /> Cl) 1. ALL MATERIALS AND CONSTRUCTION PROCEDURES WITHIN THE SCOPE OF <br /> N v S=0.0050 INV 16.33 6"W THIS CONTRACT SHALL CONFORM TO ALL APPLICABLE SAN JOAQUIN <br /> 8 25 RIM 1 7 9.98 6"SS ri COUNTY STANDARD SPECIFICATIONS(LATEST EDITION)AND THE <br /> BUILDING H NIM 16.47 6"E 6 SS CALIFORNIA DEPARTMENT OF TRANSPORTATION STANDARD <br /> 0 0 0 0 0 0 0 02LF @S=0.0050 SPECIFICATIONS(LATEST EDITION). <br /> 0"FS <br /> 10 <br /> 11 <br /> O EXISTING UTILITIES <br /> (V <br /> O <br /> CD <br /> O <br /> 1. EXISTING UTILITY DATA SHOWN ON THIS LAYOUT WAS OBTAINED FROM A REVISIONS: <br /> SURVEY OF THE VISIBLE FEATURES AT THE SITE AND PUBLIC RECORD 08-I I-22 <br /> `lCD J MAPS OBTAINED FORM UTILITY COMPANIES. PC I CORRECTIONS <br /> LOO co 09-14-22 <br /> CD U_ Z� PC 2 CORRECTIONS <br /> 0o 0 2. THE CONTRACTOR SHALL NOTIFY ALL UTILITY COMPANIES WITHIN 48 <br /> UI 1) HOURS PRIOR OF CONSTRUCTION TO LOCATE AND TAG THEIR <br /> @) UNDERGROUND FACILITIES PRIOR TO EXCAVATION. <br /> LL <br /> o J <br /> CD O° 3. THE CONTRACTOR NEEDS TO ALLOW FOR THE POSSIBILITY OF <br /> o I 0 0 0 0 0 0 0 UNDETECTED UNDERGROUND UTILITIES.ALSO,THE CONTRACTOR MUST <br /> SSWYE 5 ALLOW FOR CHANGES DUE TO UTILITIES BEING IN LOCATIONS DIFFERENT <br /> z INV 15.89 6"N FROM THOSE SHOWN ON THE UTILITY RECORD DRAWINGS.THE <br /> a - - - INV 15.89 6"S CONTRACTOR IS RESPONSIBLE FOR LOCATING AND EXPOSING CONFLICTS <br /> INV 15.89 6"W PRIOR TO CONSTRUCTION. <br /> SSCO 4 <br /> 4. THE LOCATIONS AND DEPTHS OF EXISTING UTILITIES SHOWN ON THESE <br /> _j 1/2" RIM_18-..88 \_0_ PLANS ARE APPROXIMATE ONLY.ACTUAL LOCATIONS AND DEPTHS OF <br /> 4 8 <br /> SSCIO 5 INV 15.88 6 N <br /> u-i RIM 19.98 INV 15.88 6"S UTILITIES MUST BE VERIFIED BY THE CONTRACTOR PRIOR TO <br /> U 4 g INV 6.04 6"E 6"SS CONSTRUCTION. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO <br /> 29LF @ 10 <br /> SSWYE 1 SSCO 1 0 SSCO 2 LOCATE UTILITY SERVICE LINES AS REQUIRED FOR CONSTRUCTION AND <br /> CD INV 13.23 6"E RIM 19.98 SSWYE 2 SSWYE 3 RIM 19.97 4 O 0 S=0.0050 NOTIFY THE ENGINEER OF ANY CONFLICTS IMMEDIATELY.ANY DAMAGE BY <br /> INV 14.37 6"S SDPOC 1 O =1 SDDI 7 <br /> INV 13.23 6 W INV 13.44 6"S INV 13.31 6"E INV 14.26 6"E 4 RIM 17.92 THE CONTRACTOR TO EXISTING UTILITIES,WHETHER SHOWN ON THE <br /> � INV 13.23 6"S INV 13.31 6"W 0 INV 14.26 6"W 0 INV 19.42 6"S 16 INV 13.29 15" PLANS OR NOT,SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO <br /> ILLI 6"SD o INV 13.29 15" REPAIR,AT HIS EXPENSE. <br /> � I SDDI 5 1 .31 6"N INV 14.26 6"N , o <br /> z RIM 17 60 <br /> 00 ° � °' � <br /> INV 14. 5 12"N ' 4LF S=0.010 <br /> INV 13.29 12" <br /> DP 4 -SDPOC 3 0 I- OC 2 O U <br /> 6"SS IN 19.50 6"S 4 INV 19.41 6"S 4 SS INV 19.50 6"S 4 `n <br /> 0 <br /> N 26LF "SD 6"SD 22LF @ S=0.0050 6"SD o 15 1 <br /> z 15 =0.0050 = CURB-O-LET 1 pp0 <br /> 11 LF 1 12LF S=0.0100 12LF S=0.0100 <br /> 0 6 SD CURB-O-LET 3 \CURB-O-LET 2 27 INV 19.38 6"N SSWYE 4 <br /> 15LF 6 Si INV 15.66 6"E <br /> @ 27 CURB-O-LET 4 27 INV 19.29 6"N 27 INV 19.38 6"N <br /> m S=0.0050 5LF INV 19.39 6'N <br /> INV 15.66 6"W <br /> 1 <br /> V S 0 �, �._ 11 - 1, _,/1' . �� - - '� i._ INV 15.66 6�r <br /> V) <br /> -SS 6"SS „ <br /> SS <br /> I - 3-0.0054 <br /> . 9 15"Sp 2LF 10 <br /> 15"S D <br /> Iz 6 21 1 10 219LF @ S=0.0020 121 LF @ S=0.0020 S=0.0050 <br /> w 10"FH 10"FH 10"FH 23 <br /> SSPS 1 SEPTIC TANK 1(OUT) SEPTIC TANK 1(IN) 4W 112" <br /> o RIM 18.34 RIM 18.70 RIM 18.94 16 RIM 1817 6"E .80 9 10 16 ORIM 18.80 10 SDDI 8 SSCO 3 <br /> INV 16.08_2"N _ _ INV 12.92_6"W _ _ _INV13.- - - - - - - - - - - - - - - - - -INVU.0 15"E- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 16 - - 8 <br /> - - - - �W 13-61-- FW- STM fiJ.OrT 1ztM 9,C5 - - - - - - 1 <br /> INV 12.85 6"E INV 12.92 6"E INV 13.17 6"W �'� �" ��" �' �'� <br /> J 6' INV 13.66 15"E INV 13.42 15"W INV 15.67 6"W PROJECT: 17017 <br /> 32LF @ S=0.0050 INV 13.42 15"N E i ALL WORK ASSOCIATED f:\17projects\17017 holly sugar industrial\improvement <br /> N � � � � � � � � � � � � � � � � � � � � FILE: plans\BUILDINGS H&I\Onsite\17017-05.1-UTILITY PLAN I.dwg <br /> SS STUB �� <br /> • • • • WITH BUILDING H SHALL BE <br /> z INV 13.39 6"N 2 • - • _ • - . . ULTIMATE RIGHT . WAY . - •� - - . _ -• _ - 12 • 13 22 <br /> _ - DATE: 9/13/2022 <br /> _ 5 - H OH OH _OH OH OH Or, _ �H OH -YR - U; er OH/-L OH O OH 01 -•OH 'OW- OH•- � � � � � � � � � OH OH OH OH � I PERFORMED UNDER <br /> C0 Z- - - - - RIM 15.o - N - - - - - - - - - - - - �' ESDc6 / DRAWN BY: LSF/MWK <br /> o O � �ES�DjXISTINGRIGHTOFWAY RIM 16.27 0 U_ BUILDING PERMIT #2202552 <br /> INV 9.21 12"S INV 9.3212 S <br /> SHEET TITLE: <br /> 0 0CB <br /> _ - RIM 18.42 - - - - ARBOR AVENUE � RIM 19oo - - - - 12W - - - - - <br /> UTILITY PLAN <br /> 0INV 11.52 12"N <br /> 0 0 12 W INV 9.22 12"S 12 W INV 9.55 12"S <br /> INV 8.9718"E - - - - - INV 9.5018"W <br /> - - - - - - - - - - --= o <br /> o <br /> 1114V O.U1 10 VV <br /> U NLIJ <br /> N <br /> 0 Know what's below. 0 <br /> _ _ _ _ _ _ _ _ ' 10' 20' 40' <br /> Call before you dig. - - - . - . _ - . - . - . - . - - - . . <br /> - SCALE: 1"=20' c5m 11 <br /> L - - K-A <br /> UNIFORM DRAWING SYSTEM - U.S.NATIONAL CAD STANDARD VERSION 3.1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.