KEY NOTES LEGEND ■ <br /> OPROPOSED FIRE HYDRANT PER DETAIL 1 ON SHEET C7.1 - HOSE PULL(350'MAX BY TRUCK) <br /> O VEHICULAR ACCESS GATE W/KNOX BOX AND HOSE PULL(150'MAX BY HAND) <br /> SIREN ACTIVATED SENSOR <br /> O 10"DOUBLE CHECK DETECTOR BACKFLOW PREVENTION ASSEMBLY PROPOSED AERIAL APPARATUS ACCESS <br /> FOR FIRE LOOP PER DETAIL 18 SHEET C7.0 <br /> O4 EXISTING FIRE HYDRANT OR PROPOSED OFFSITE FIRE HYDRANT PROPOSED FIRE HYDRANT <br /> FIRE PUMP ROOM SEE FIRE PROTECTION PLAN FOR EXISTING FIRE HYDRANT S I E G F R I E D <br /> O ADDITIONAL INFORMATION <br /> EXISTING WATER LINE <br /> O PROPOSED FIRE DEPARTMENT CONNECTION Stockton, <br /> Brookside Road <br /> 8"FS PROPOSED FIRE SERVICE WATER LINE Stockton,California 95219 <br /> 209-943-2021 <br /> O ALL RISERS SHALL BE PLACED AT EXTERIOR EXIT ACCESS FIRE TRUCK LANE STRIPING Fax: 209-942-0214 <br /> DOORS AND SHALL BE LABELED WITH APPROPRIATE SIGNAGE www.siegfriedeng.com <br /> 0 FIRE TRUCK LANE <br /> FIRE PROTECTION NOTES oQ�o scs �o <br /> 1. FIRE LANES SHALL HAVE A MINIMUM 2-WAY TRAFFIC WIDTH OF 26 FT.WITH <br /> A MINIMUM INSIDE TURNING RADIUS OF 29'-9"AND A MINIMUM OUTSIDE <br /> TURNING RADIUS OF 47'-7"FT., UNLESS OTHERWISE NOTED. <br /> 09/3 /23 <br /> 2. FIRE APPARATUS ACCESS ROADS SHALL NOT BE OBSTRUCTED IN ANY J'J9 CN�L ��\P <br /> MANNER. NO OBSTRUCTIONS SHALL INTERFERE WITH EMERGENCY lFOF CN <br /> OPERATIONS AND BETWEEN THE FIRE APPARATUS ACCESS ROADS AND <br /> BUILDING. <br /> DATE SIGNED:-09/13/22 <br /> 3. AREAS INDICATED AS AERIAL APPARATUS ARE INCLUDED TO ILLUSTRATE <br /> CODE COMPLIANCE ONLY. NO SPECIAL PAVING,STRIPING OR SIGNAGE <br /> SHALL BE REQUIRED FOR THESE AREAS. <br /> 4. ALL ACCESS GATES SHALL BE EQUIPPED WITH TRAFFIC PREEMPTING <br /> . . . . . . .—. .—. .—. .—. . . <br /> OPTICAL SIGNAL RECEIVERS COMPATIBLE WITH EMITTERS USED BY THE <br /> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . <br /> . . . . . . . . . . . . . . <br /> . . . . . . . . . . . . . . . . . . . . <br /> FIRE DEPARTMENT,WHICH WILL ACTIVATE THE GATES AND OVERRIDE ALL <br /> \ \ <br /> \ \ <br /> COMMAND FUNCTIONS OF THE GATE CONTROLLER ELECTRIC GATE <br /> \ R50'. OPERATORS SHALL BE LISTED IN ACCORDANCE WITH UL 325.AUTOMATIC <br /> .—. ..—. . .�. . . . . . . . <br /> . . . . . . . . . . . . . . <br /> 10 . . . . . . . . .. I I GATES SHALL BE DESIGNED, CONSTRUCTED AND INSTALLED TO COMPLY <br /> 26' FIRE TRUCK LANE WITH THE REQUIREMENTS OF ASTM F2200.ALL ACCESS GATES SHOULD <br /> PROVIDE FIRE DEPARTMENT KNOX BOX,WITH SWITCHES ON BOTH SIDES <br /> R30' \ I OF THE GATES.AUTOMATIC GATES SHALL HAVE A BATTERY BACK-UP OR A <br /> R30 <br /> 10"FH MANUAL MECHANICAL DISCONNECT READILY ACCESSIBLE TO EMERGENCY <br /> a PERSONNEL IN CASE OF POWER FAILURE. <br /> n <br /> . . . . . . . I. . . . . . . . . . . I 5. ALL ACCESS GATES AND EMERGENCY OPERATION SHALL BE MAINTAINED <br /> OPERATIONAL AT ALL TIMES. <br /> 6. CONTRACTOR SHALL REFERENCE ARCHITECTS PLANS AND COORDINATE W/ <br /> .......... .......I I FIRE MARSHALL FOR THE PLACEMENT OF REQUIRED, PERMANENT, "NO <br /> PARKING-FIRE LANE"SIGNS&STRIPING THROUGHOUT THE SITE. SIGNS <br /> I.:...:.:.:.:.:.:.. . SHALL HAVE A MINIMUM DIMENSION OF 12 INCHES WIDE BY 18 INCHES HIGH <br /> 0 <br /> ,i I AND HAVE RED LETTERS ON A WHITE REFLECTIVE BACKGROUND. <br /> : I <br /> I R50' /. . . . . . . . . .—:.:. . . . . . .—. .—. .—. .—. .—. .—. .—. .—. . . . . . .—. .—. .—. .—. .—. . .—. .—. . .�•-. . . . . . . . . 7. ALL 12", 10",8",AND 6"WATER MAINS SHALL BE PVC PIPE, CLASS 150, <br /> . I: <br /> MEETING AWWA C900 STANDARDS. <br /> . . .:. . . .:. . . . . . . .:. . . . . . . . . . . . . . . . . . . . . . . . . . : . . : : : . : : : : : : . . : : : . : : : : : . 2 . . . . . . . . . . . . . . . . . . . . . . . . . .R30 I <br /> . . . . . . . . . . <br /> 8. ACCORDING TO TABLE C105.1 OF THE CALIFORNIA FIRE CODE THE SITE <br /> . �_ I I : : : : : : : : I <br /> SHOULD HAVE FIRE HYDRANTS SPACED A MAXIMUM OF 400 FEET APART <br /> DUE TO THE FIRE FLOW REQUIREMENT OF 2000 GPM, DEPICTED IN THE <br /> �. . . . . .:. . . . . . / R30' . . I I PLAN THE SITE MEETS THIS REQUIREMENT. <br /> /� R30' FIRE TRUCK LANE �. . . I I . . . . . . . . . I <br /> ". O 9. EMERGENCY RESPONDER RADIO COVERAGE MAY BE REQUIRED FOR THE <br /> 10"FH 1 H. 10"FS 10"FH 10"FH. I I TENANT SPACE. TEST SHALL BE DONE PRIOR TO FINAL INSPECTION. <br /> 26 PHELAN <br /> : : <br /> 1 <br /> �� 8"FH I D EVELOPM ENT <br /> 1 10TS FIRE PUMP ROOM NOTES 450 Newport Center Drive, Suite 230 <br /> . . . . . . . . . . . . . 1 7 <br /> Newport Beach, CA 92660 <br /> .I . . . I I I . . . <br /> . . : . : . . . . . . TEST HEADER AND FIRE DEPARTMENT CONNECTION <br /> o � � . PROPOSED BUILDING I <br /> 1. TEST HEADER-THIS MANIFOLD INCLUDES HOSE VALVES TO WHICH HOSE IS <br /> . . . \ . I bUILUINU I I.'.'.'.'.'. .'.'.'. <br /> ATTACHED TO WHEN TESTING. THE REQUIRED NUMBER OF HOSE VALVES <br /> 7 7 \ <br /> 1 AND THE MINIMUM SIZE OF THE HOSE ARE BASED ON THE RATING OF THE <br /> Q <br /> I <br /> \ I FIRE PUMP AND ARE INDICATED ON TABLE 5.25 OF NFPA 20(2003 EDITION). BUILDINGS H& <br /> I. . . . . . . I o 8 FH I 2. TEST HEADER SUPPLY PIPE THE MINIMUM PIPE SIZE IS INDICATED ON HOLLY COMMERCE CENTER <br /> I. . . . . . . . . R30' I TABLE 5.25 OF NFPA 20(2003 EDITION). UNLESS SIZED HYDRAULICALLY, IF <br /> THE LENGTH OF PIPE BETWEEN THE TEST HEADER AND THE CONNECTION <br /> TO THE DISCHARGE SIDE OF THE PUMP EXCEEDS 15 FEET THE NEXT <br /> 1 I I I LARGER NOMINAL PIPE SIZE MUST BE USED(NFPA 20, SECTION 5.19.3.4). <br /> r : : : I . : 9375 SUGAR RD <br /> . .� 3. CONTROL VALVE-THIS CONTROL VALVE MUST BE INSTALLED IF THE <br /> Rao'. . I I . . . . . . . . I TRACY, CA 95304 <br /> k I. . . . . . ..... <br /> . . . . . .� � LOCATION OF THE TEST HEADER IS SUBJECT TO FREEZING. THIS VALVE <br /> R32 = I MAY BE OS&Y OR BUTTERFLY TYPE. NFPA 20, SECTION 5.16.2 REQUIRES <br /> I . : . :. .:. .. 26 I THIS VALVE TO BE SUPERVISED CLOSED. A DRAIN VALVE OR BALL DRIP <br /> PROPOSED BUILDING <br /> I 5 1 SHALL ALSO BE INSTALLED. <br /> BUILDING H I _ I MILESTONES: <br /> 26. . . . \ <br /> 4. TEST HEADER CONNECTION-THE CONNECTION FOR THE TEST HEADER 28 JANUARY 2022 <br /> R70 SHOULD BE BETWEEN THE DISCHARGE CHECK VALVE AND THE DISCHARGE BUILDING DEPARTMENT SUBMITTAL <br /> _ I I CONTROL VALVE. THIS ALLOWS THE FIRE PUMP TO BE TESTED WITH THE <br /> 40'RADIUS FROM THE FIRE HYDRANT LOCATION. DOORS I. . . . . . . I DISCHARGE CONTROL VALVE CLOSED, ISOLATING THE PUMP FROM THE <br /> . AND WALLS WITHIN RADIUS SHALL BE NON-COMBUSTABLE �❑ 6 \ . . . . . . . . . . . . . . . . . . 10"FS 7 REST OF THE SYSTEM. <br /> I : : I AND THE DOOR SHALL BE FIRE RATED.TYPICAL . . . R127 <br /> . . . _ Q. . . . . 5. FIRE DEPARTMENT CONNECTION(FDC)-IT IS IMPORTANT THAT THE FDC BE <br /> TIED INTO THE DISCHARGE SIDE OF THE FIRE PUMP ON THE SYSTEM SIDE <br /> V I OF THE DISCHARGE CONTROL VALVE. <br /> . . . . . . . . <br /> I 2 R60 40'RADIUS FROM THE FIRE HYDRANT J <br /> I . . . . . LOCATION. DOORS AND WALLS WITHIN <br /> RADIUS SHALL BE NON-COMBUSTABLE AND <br /> I THE DOOR SHALL BE FIRE RATED.TYPICAL 1 <br /> I. . . . . . . . . .I I . . . . . . . . / : : : : : : REVISIONS: <br /> LLJI 40' �O PC I CORRECTIONS <br /> �. : : . : R30' o o R25' ❑ <br /> R25 09-14-22 <br /> R25' R29' R187' I 1 PC 2 CORRECTIONS <br /> 1 26' 1 26' FIRE TRUCK LANE 26' 1 <br /> ® f : - - - - - - - - - - / - - - - - - - - - - - - - - - - - - - - - - - <br /> . . . . . . . . . . . . . . . . . . . . . . . _ - <br /> . . . . . . . . . . . . . <br /> „ - - <br /> 1. .F <br /> c� <br /> . . . . . . . . . . . <br /> 0 <br /> 10TH <br /> 10"F' . . <br /> I. . . . . . . . . . . . . . . . 42RMN <br /> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . _ .__ ———— — — __ — _.—.——.—.—.T/. . . . . . . . . . . . . . . . <br /> . . . . . . . . . . . . . . . . . . . . . . . - - - - - - - -...... .... — — - - - - - - - - -.—.—.—.—.—.—. ,4•WW <br /> o - <br /> - — —. —.—. �.�.—.—.— — — — — — — — — — . T __ — — — — — — —.—.—.r.—.—.—.— — — — — — T T __ __ — — —— — — — .� — — W <br /> f 6 . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . <br /> Z . . . . . . . . . . . . . . . . . . . . . . . . . . <br /> . . . . . . . . . <br /> —. . . . . . . . . . . . .—. . — — — 4 <br /> .,.^.,.ate . . . . . . . . . +/ <br /> 77� <br /> w -. .- . . . . . . . R13' — — — — — — r — — R13' R13' R13' ® R1 3' <br /> v FIRE TRUCK LANE ULTIMATE RIGHT OF WAY <br /> _ _ <br /> 3 �� A — - - - - - e — - - - � - - - ARBOR AVENUE - - - <br /> LLIEXISTING 12 STUB. EXISTING RIGHT OF WAY <br /> ry <br /> � — <br /> I <br /> — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — J-L — — — — — — — <br /> L_ _ <br /> 00 <br /> V b � �� /� � � \ / - - - - - - - - � ® � _F <br /> UJI <br /> ' I <br /> - - - - <br /> o <br /> cn A\ \ <br /> J ------------ <br /> TD <br /> 1 <br /> ZN / I — — - — — — — — — — — — — — ` — — + — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — I <br /> — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — <br /> � <br /> z \ \ I <br /> w — — — — — <br /> LLI <br /> o — — — — — — — — — — — — — — — — — — — — — \ — — — — — • <br /> \ \ I PROJECT: 17017 <br /> I ALL WORK ASSOCIATED <br /> f:A17projects\17017 holly sugar industrial\improvement <br /> (n — <br /> o v\ v� 1 SHALL� � WITH BUILDING H B E .� FILE. plans\BUILDINGS H&I\OnsiteA17017-C8.0-FIRE ACCESS <br /> PLAN.dwg <br /> Z I 1 PERFORMED UNDER DATE: 9/13/2022 <br /> CD <br /> 1 BUILDING PERMIT #2202552 DRAWN BY: LSF/MWK <br /> SHEET TITLE: <br /> 0 1 I FIRE ACCESS PLAN <br /> 0 <br /> o 1 <br /> Q Q 0 <br /> o� 1 <br /> U <br /> UJI <br /> 0 <br /> 0 Know what's below. 1 I 0' 20' 40' 80' <br /> Call before you dig. 1 I C8mO <br /> 1 I I SCALE: V=40' <br /> UNIFORM DRAWING SYSTEM - U.S.NATIONAL CAD STANDARD VERSION 3.1 <br />