Phelan Development Holly Master Plan - Buildings H & 1 <br /> 15188.000.006 Geotechnical Exploration <br /> Minimum footing depths shown above are taken from lowest adjacent pad grade. The cold joint <br /> between the exterior footing and slab-on-grade should be located at least 4 inches above adjacent <br /> exterior grade. <br /> For areas where overexcavation of undocumented fill and placement as engineered fill is <br /> completed, or for areas bearing on competent native soil, design foundations recommended <br /> above for a maximum allowable bearing pressure of 1,500 pounds per square foot (psf)for dead- <br /> plus-live loads Increase this bearing capacity by one-third for the short-term effects of wind or <br /> seismic loading. Maximum allowable bearing pressures where ground improvements are <br /> incorporated would depend on design conditions specific to the ground improvement and will be <br /> determined at a later time if ground improvement is utilized at the project. <br /> The maximum allowable bearing pressure is a net value; the weight of the footing may be <br /> neglected for design purposes. Footings located adjacent to utility trenches should have their <br /> bearing surfaces below an imaginary 1:1 (horizontal:vertical) plane projected upward from the <br /> bottom edge of the trench to the footing. <br /> 6.2.2 Reinforcement <br /> The structural engineer should design footing reinforcement to support the intended structural <br /> loads without excessive settlement. <br /> 6.2.3 Foundation Lateral Resistance <br /> Lateral loads may be resisted by friction along the base and by passive pressure along the sides <br /> of foundations. The passive pressure is based on an equivalent fluid pressure in pounds per cubic <br /> foot (pcf). We recommend the following allowable values for design. <br /> • Passive Lateral Pressure: 300 pcf <br /> • Coefficient of Friction: 0.25 <br /> Passive pressures should be reduced by 1/2 if used in combination with sliding friction. The above <br /> passive pressure assumes a horizontal distance of at least 10 feet from the foundation to daylight. <br /> The upper 1 foot of soil should be excluded from passive pressure computations unless it is <br /> confined by pavement or a concrete slab. <br /> 6.2.4 Settlement <br /> Provided our report recommendations are incorporated in to the design and construction of the <br /> proposed project (as described in Section 1.3), we estimate static total foundation settlements to <br /> be less than approximately 1 inch. We estimate approximately '/4 inch of differential settlement <br /> between exterior and interior footings. In addition, we estimate approximately % inch over 50 feet <br /> of differential settlement in the event of a design level earthquake. We recommend structures be <br /> designed to accommodate up to '/2 inch of differential settlement over a distance of 50 feet for <br /> static and seismic conditions. <br /> ENGEO Page 1 17 December 13, 2021 <br /> Expect Exceltence <br />