Laserfiche WebLink
File No. S-1739-1 <br /> H. KLEINFELDER & ASSOCIATES October 27, 1982 <br /> TABLE I <br /> SUMMARY OF FIELD DENSITY TEST RESULTS <br /> Dry Laboratory Specified <br /> TestMoisture Density Compaction Relative Relative <br /> No. Dote Test Location FSG* % Dry Wt. P.C.F. Curve No. Compaction Compaction <br /> CEN TI-ER-TIUMUTH HAJF_0T-PrT_NU. 4 BO <br /> 35 10-19 N End of S Half PSG 15.5 113.0 3 98 90% <br /> 36 10-19 Center of S Half PSG 17.1 109.3 3 95 90% <br /> 37 10-19 S End of S Half PSG 12.2 112.4 3 98 90% <br /> 38 10-20 N End N Half PSG 16.4 109.9 3 96 90% <br /> Pit #4 <br /> 39 10-20 S End N Half PSG 15.6 103.7 3 90 90% <br /> Pit #4 <br /> 40 10-20 S WW Pond SE Cor PSG 17.6 106.2 3 92 90% <br /> 41 10-20 S WW Pond SW Cor PSG 16.6 109.3 3 95 90% <br /> 42 10-20 S WW Pond NW Cor PSG 16.9 103.6 3 90 90% <br /> 43 10-20 S WW Pond NE Cor PSG 13.8 104.2 3 91 90% <br /> -2.0 <br /> 44 10-20 Center WW Pond PSG 18.4 105.5 3 92 90% <br /> SE Corner <br /> 45 10-20 Center WW Pond PSG 18.0 103.7 3 90 90% <br /> NE Corner <br /> 46 10-20 Center WW Pond PSG 15.7 103.0 3 90 90% <br /> Center -2.0 <br /> 47 10-20 Center WW Pond PSG 17.7 105.5 3 92 90% <br /> NW Corner <br /> 48 10-20 N WW Pond PSG 18.4 105.'5 3 92 90% <br /> NE Corner <br /> 49 10-20 N WW Pond PSG 18.8 103.0 3 90 90% <br /> SE Corner <br /> 50 10-20 N WW Pond PSG 16.8 108.0 3 94 90% <br /> NW Corner <br /> 51 10-20 N WW Pond PSG 17.6 110.5 3 96 90% <br /> SW Corner <br /> *DENOTES FINISHED SUBGRADE <br /> "Denotes Waste Water <br /> Accepted engineering and testing procedures were used for these tests. The above data is presented for in- <br /> formaf'ion purposes only. In the absence of continuous observations of our personnel at the site, we can not <br /> express an opinion as to the adequacy of site preparation or overall fill compaction. We do not undertake the <br /> guarantee of construction, nor do we relieve the contractor of his primary responsibility to produce a com- <br /> pleted project conforming to the project plans and specifications. <br /> IHK&A Form R-20 <br />