Laserfiche WebLink
USTCOCC88-74 <br /> Environmental Health Division <br /> San Joaquin Local Health District <br /> Page 3 <br /> 2. Sewer and Water Lines <br /> The attached map shows the location of sewer and water lines at the <br /> southern end of the property. The planned boring locations meet <br /> the minimum setback requirements of 50 feet from the sewer lines and <br /> 10 feet from structures. <br /> 3. Laboratory Analysis <br /> California Water Labs will be retained to perform the laboratory <br /> analysis. Selected soil samples will be analyzed for BTX&E (8020) , <br /> total petroleum hydrocarbons in the gasoline, diesel and oil range <br /> (5030, 3550) , and organic lead (DOHS-LUFT) . These analyses combined <br /> with the proposed OVM field screening should provide an effective means <br /> of determining the potential for contamination at the site. <br /> 4. Underground Tanks <br /> In the event that underground tank or tanks are identified during our <br /> investigation, registration and proper abandonment of the tanks will be <br /> performed in accordance with the San Joaquin Local Health District <br /> program requirements. <br /> Thank you for taking the time to review our proposal. If you have any <br /> questions regarding this project please give us a call. <br /> UNITED STATES TESTING COMPANY, INC. <br /> Respectfully submitted, <br /> illiam M. Schill <br /> Environmental Project Manager <br /> WMS/bc <br /> Enclosure PAYMENT <br /> RECEIVED <br /> AUG 3 11988 <br /> ENVIRONMENTAL HEALTH <br /> PERMITISERVICES <br />