<br /> El HAZMAT Transport ❑For incidental release/spill;maintain spill kit suitable for low flammability/toxicity/quantity/volatility release.
<br /> El DOT/TDG/IATA-Regulated transport:see D.17."Hazmat/Dangerous Goods Shipping/Transportation.
<br /> ❑Risk of Emergency Spill/Release ❑For emergency spills:describe spill/release hazard and response plan/procedure above,and indicate
<br /> El CFTAS(Chemical Facility Anti- emergency response contact in Part B,"Emergency Response and First Aid."
<br /> Terrorism Standards)Applicability: ❑Locate emergency gear(eyewash,fire extinguisher,spill kit,safety signage)near storage area,as applicable.
<br /> On-site overnight storage of non- ❑For CFTAS-applicable chemical storage,a safety and chemical management plan must be prepared and
<br /> waste chemical product at quantity reviewed by a H&S Professional before bringing material to the site.(Does not apply to materials brought on to
<br /> >25 gal(115L)or>250 lbs.(115 kg) the site for daily work purposes and transported away at the end of each day)
<br /> ® ; COMPRESSED GAS CYLINDERS ©Secure cylinders upright,caps on when not in use.
<br /> i ®Flammable € ® Handle with care;use and store cylinders in a manner and location to prevent damage.
<br /> ❑Non-flammable ❑Propane cylinders not in use must be stored outdoors in a cage or similar secure ventilated enclosure.
<br /> ❑Toxic ❑Ensure acetylene cylinders are NOT secured to steel arc welding bench.
<br /> ❑Asphyxiant ❑Segregate oxygen and fuel gases by distance(20')or fire-rated barrier.
<br /> ❑Oxygen M Control ignition sources.
<br /> ❑"No smoking"signage at cylinder storage area for flammable gases.
<br /> ® FLAMMABLE/COMBUSTIBLE ® Use proper fuel safety can(metal fuel container with self-closing spout and flame arrestor preferred).
<br /> LIQUIDS ®Control/remove ignition sources near storage and use areas.
<br /> ❑Grounding and bonding where appropriate.
<br /> ® Ensure a Type B or ABC fire extinguisher is readily available.
<br /> ; ACIDS,CAUSTICS,OTHER ❑Use appropriate protection for eyes/face(goggles/face shield)and skin(gloves,sleeves,apron).
<br /> CORROSIVES ❑Use eyewash,deluge shower,drench hose,hand washing(with water),as appropriate.
<br /> ❑For severe eye hazards(due to high corrosivity,large quantity),15-min.eyewash required.
<br /> TOXIC ❑For toxic substances,use/store in a manner to control exposure hazards(inhalation,ingestion,skin contact,
<br /> skin absorption);use active ventilation and/or PPE as appropriate.
<br /> ` EMISSIONS FROM FUEL ® Position outdoor personnel upwind of exhaust source.
<br /> COMBUSTION,HOT PROCESSES ®Avoid"idling"of equipment when not in use.
<br /> ®Gasoline ❑Use passive ventilation(air infiltration/air currents)to disperse atmospheric hazards in breathing zone.
<br /> ❑Diesel ❑Use dilution ventilation(blowers/fans)to provide fresh air to work area and dissipate atmospheric hazards.
<br /> ❑Propane/Natural Gas ❑Use exhaust ventilation(hood/duct/exhaust stack/blower)to capture/divert exhaust from work area.
<br /> ❑Weld ing/cutting/hot work ❑Use respiratory protection for high levels of smoke,exhaust particulates,soot.
<br /> ❑Vehicle/equipment exhaust ❑Conduct air monitoring as appropriate;see Part E;'Air Monitoring,Worker Exposure Monitoring."
<br /> ❑Other
<br /> ; OTHER HAZARDS ❑Describe other hazardous substances and safety measures under"Site-Specific Notes&Clarifications,"above.
<br /> Geosyntec Procedures: HS-115-US-Hazard Communication,HS-115-CA-WHMIS,HS-111-Air Monitoring,HS-112-Respiratory Protection,
<br /> HS-113-Personal Protective Equipment,HS-114-Safety Training Programs,Others as applicable
<br /> D.15. SITE CONTAMINANTS, CHEMICAL WASTES ® Applicable ❑ Not Applicable, Not Anticipated
<br /> Site-Specific Notes&Clarifications: Off-site soils are not believed to be impacted by site CDCs.Off-site groundwater may potentially have low levels of some
<br /> site COCs. Recent groundwater monitoring for the shallow water-bearing zone indicated the following constituent concentrations:
<br /> o Nitrate as nitrogen:from non-detect(less than 0.01 mg/L)to 878 mg/L in MW-6;
<br /> 0 1,2-Dichloropropane:non-detect to 970 WJL in MW-58;
<br /> 0 1,2-Dibromo-3-chloropropane:non-detect(less than 0.007 pg/L)to 0.031µg/L in MW-SB;
<br /> 0 1,2,3-Trichloropropane:non-detect(less than 0.003µg/L)to 8.8 WJL in MW-SB;
<br /> o Dinoseb:non-detect(less than 0.08µg/L)to 3.1 WJL in MW-10;
<br /> o Other halogenated volatile organic compounds:Chloroform(0.1µg/L at MW-10),1,3-Dichlorobenzene(0.14µg/L and 0.17 M/L at MW-56 and
<br /> MW-10,respectively),and 1,4-Dichlorobenzene(0.33µg/L at MW-56);
<br /> o Carbamate herbicides:Bromacil(from 2.0 to 34 M/L at monitoring wells MW-5B,MW-6,MW-7,MW-8,and MW-10),Diuron(from 0.8 to 4.6
<br /> µg/L at monitoring wells MW-5B,MW-6,MW-7 and MW-8),and Tebuthiuron(1.2µg/L at MW-8);
<br /> o Triazine herbicides:atrazine(0.33 and 0.88µg/L at monitoring wells MW-7 and MW-8,respectively);and
<br /> o Chlorinated herbicides:Dicamba(0.54µg/L at monitoring well MW-5B).
<br /> CHECK ALL THAT APPLY. Provide site-specific notes/clarifications above.
<br /> ®Soil/groundwater contaminants(historical release) ❑Explosive dust ❑Potential for flammable gas(methane)
<br /> ❑Recent release,known high concentrations ❑Oxygen deficiency ❑Corrosive,acids/caustics,strong irritants
<br /> ❑Former chemical disposal site,landfill ®Chlorinated volatile organic compounds(VOCs) ❑Asbestos abatement work
<br /> ❑Urban fill,residual contaminants ❑BTEX,petroleum derived VOCs ®Pesticides,herbicides,fungicides
<br /> ❑Containerized waste(drums,process equipment) ❑Fuel oils,petroleum,waste oil,lubricants ❑Sensitizers
<br /> ❑Buried drums(known or potential) ❑Metals,metal compounds,metal dusts ❑Radioactive contaminants
<br /> Geosyntec Project/Task Name:TR0712/GSH OxyChem-Stockton SVP Installation
<br /> THA Date:06/25/2022 Page 12