Laserfiche WebLink
hydraulic control of shallow groundwater and to remove nitrate and volatile organic compounds from soil <br /> and groundwater. Three of the Oxychem monitoring wells are screened at a deeper interval (ranging from <br /> 60 to 90 feet below ground surface); the locations of these three deeper zoned Oxychem wells are shown <br /> on Figure 4(Appendix A). <br /> 4.2 WELLS WITHIN 500 FEET OF THE SITE <br /> Based on Condor's review of DWR's well records and communications with property owners,the City of <br /> Stockton Municipal Utilities Department, and California Water Service staff, no wells are located within <br /> 500 feet of the site. The closest well is an industrial well used for fire suppression purposes located <br /> approximately 1,250 feet northeast of the site. <br /> 4.3 OTHER POTENTIAL RECEPTORS <br /> Condor reviewed aerial, topographic, and city street maps, California's GeoTracker and Department of <br /> Toxic Substances Control's (DTSC's) EnviroStor online geographic information system (GIS) databases, <br /> and other available public directory databases to identify other potential receptors such as schools,childcare <br /> facilities,health care facilities,parks,and other pertinent sites located within the 1,000-foot study area.Two <br /> locations were identified in the locations shown on Figure 4(Appendix A).Additional receptor information <br /> is provided in the following sections. <br /> 4.3.1 Schools and Childcare Facilities <br /> No schools or childcare facilities were identified within 1,000 feet of the site. <br /> 4.3.2 Surface Water Bodies <br /> Three stormwater basins are located in the study area. One stormwater basin is located at the southeast <br /> corner of the former Helena Chemical Facility Site parcel, one is located approximately 575 feet north- <br /> northwest on industrial property, and one is located approximately 675 feet north-northeast of the Site on <br /> industrial property.The nearest surface water body that is also a sensitive receptor is the San Joaquin River, <br /> located 2,500 feet west of the Site. The locations of the three stormwater basins are shown on Figure 4 <br /> (Appendix A). <br /> 4.3.3 Healthcare Facilities <br /> There are no healthcare facilities located within 1,000 feet of the site. <br /> 4.3.4 Parks <br /> No parks are located within 1,000 feet of the site. <br /> 4.4 PUBLIC WATER SUPPLY <br /> California Water Service(Cal Water)provides water to the study area and owns the large water tank located <br /> approximately 700 feet east-southeast of the Site. Condor contacted Cal Water to identify any of their wells <br /> within the 1,000-foot search radius. Craig Stevens, California Water Service Superintendent 11, indicated <br /> that Cal Water does not have any wells within 1,000 feet of the Site. The pump station located next to the <br /> water tank is a booster pump station tied to the distribution system and not the location of a well site. <br /> Condor also contacted the City of Stockton to identify whether any City wells were located within the <br /> 1,000-foot study area. Eric Houston, Chief Plant Operator for the City of Stockton Municipal Utilities <br /> Department, indicated that the City of Stockton does not have any wells within 1,000 feet of the Site. <br />